background image

S201 and S202 Series

6

Parts List

key  Description 

Part Number

            Spare Parts (Repair Parts Kit includes  

            keys 5, 7, 16, and 19)

              Types S201, S202 

RS201X00012

              Types S201H, S202H 

RS201HX0012

              Type S201K 

RS201KX0012 

  1 

Spring Case

 

  Aluminum 

4L142308032

 

  Pinned for heavy spring 

1J718699022 

 

  2 

Spring, Steel  

See Table 3

  3 

Adjusting Screw

 

  Aluminum (Types S201, S201H, S202, S202H) 

1L928608012

 

  Steel (Type S201K) 

1R8085T0012

  4 

Closing Cap 

 

  Aluminum (Types S201, S201H, S202, S202H) 

1L928308012

 

  Brass (Type S201K)  

1H798714012

  5*  Closing Cap Gasket, Neoprene (CR) 

1N446206992

  6 

Upper/Lower Spring Seat 

 

  Aluminum (Types S201, S201H, S202, S202H) 

1L928708012

 

  Brass, Type S201K (2 required) 

1H797414012 

  7*  Diaphragm and Diaphragm Head 

              Types S201, S202 - Use with 

 

    1D8933 and lighter springs 

1L1544X0012

 

  Types S201H and S202H - Use

 

    with 1H9758 and heavier springs 

1L1545X0012

              Type S201K (Diaphragm only) 

1K649602052

  8 

Pusher Post, Aluminum

 

  Types S201, S201H, S201K 

2H980608012

 

  Types S202, S202H 

2H975208012

  9 

Lower Casing Assembly, Aluminum/Stainless steel  1H9751X0012

  10  Lever, Steel 

1H974028992

  11  Pin, 303 Stainless steel 

1H972935032

  12  Machine Screw, Steel (2 required) 

1B420428982

  13  Valve Stem Assembly  

1H9748000A2

  14  Cap Screw, Steel (12 required) 

1B136324052

  15  Hex Nut, Plated steel (12 required) 

1A309324122

  16*  Disk Holder Assembly

 

  For Natural Gas Service 

1P7349000A2

 

  For Manufactured Gas 

 

    (3/4-inch (19 mm) larger orifices) 

1J1680X0012

  17  Diaphragm Plate, Steel (Type S201K) 

1A347825022

  18  Cap Screw, Plated steel (2 required) 

1H974724052

  19*  O-ring, Nitrile (NBR) 

T12587T0012

  20  Orifice, Aluminum

 

  1/4-inch (6,3 mm)  

T13833T0012 

 

  3/8-inch (9,5 mm) 

1H979309022

 

  1/2-inch (13 mm) 

1H979409022

 

  3/4-inch (19 mm) 

1H979509022

 

  1-inch (25 mm) 

1H979609022

 

  1-3/16-inch (30 mm) 

1H979709022

*Recommended spare part.

Note

Take care not to pinch or tear the 

diaphragm when reassembling.

  6.  Reassemble the spring case unit in the reverse  

       order of the above steps.  Before tightening the  

       cap screw or stem into the pusher post, place  

       the loosely-assembled diaphragm and diaphragm  

       head assembly into position in the lower casing,  

       being sure that the pusher post is hooked on  

       the lever.  Rotate the diaphragm so that the      

       diaphragm and lower casing holes are aligned.   

       Tighten the screw or stem.

CAUTION

Before tightening cap screws (key 14), 

replace the spring and adjusting screw.  

Turn the adjusting screw to about 

mid position.  This will stretch the 

oversized diaphragm to ensure slack in 

the assembled diaphragm.  The slack 

created by this method is necessary 

for good regulation.  Be sure the 

diaphragm does not fold over at the 

flange when reassembling.

Disassembly to Replace valve Disk, 

Orifice, and O-Rings

  1.  Remove the cap screws (key 18, Figure 5) which  

       hold the lower spring casing (key 9) to the body 

       (key 21).  Separate the lower spring casing from  

       the body.
  2.  Check the body O-ring (key 19) for wear.

  3.  Examine the valve disk (key 16) for nicks, cuts,  

       and other damage.  Unscrew the disk holder  

       assembly (key 16) and replace it with a new part 

       if necessary.

  4.  If the seating edge of the orifice (key 20)  

       is nicked or rough, remove the orifice from  

       the body.  Change to a new part when 

       reassembling the regulator.  (If the orifice is     

       replaced with a different size, change  

       the nameplate to state the new size and 

       maximum inlet pressure).

  5.  Reassemble the regulator in reverse order of the  

       above steps.

Parts Ordering

The type number, orifice size, spring range, and 

date of manufacture are stamped on the nameplate.  

Always provide this information in any correspondence 

with your local Sales Office regarding replacement 

parts or technical assistance.  
When ordering replacement parts, reference the key 

number of each needed part as found in the following 

parts list.  Separate kit containing all recommended 

spare parts is available.

Summary of Contents for Fisher S202

Page 1: ...ulator Warning Figure 1 Typical S200 Gas Regulator W1919 Introduction Scope of the Manual This instruction manual provides instructions for installation adjustment maintenance and parts ordering information for Types S201 S201H S201K S202 and S202H gas service regulators Description S201 and S202 Series regulators are typically installed on industrial and commercial applications The Types S202 and...

Page 2: ...Typical start to discharge values are 7 inches w c to 2 psi 17 to 138 mbar above the outlet pressure setting depending on control spring used Available Configurations See Figure 3 Body Size and End Connection Styles 1 1 2 or 2 NPT inlet and outlet and NPS 2 DN 50 CL125 FF flanged Maximum Allowable Inlet Pressures 1 See Table 1 Maximum Emergency Outlet Pressure 1 15 psig 1 0 bar Outlet Pressure Ran...

Page 3: ...utdoor installations point the spring case vent downward to allow condensate to drain see Figure 4 This minimizes the possibility of freezing and of water or other foreign materials from entering the vent and interfering with proper operation Under enclosed conditions or indoors escaping gas may accumulate and be an explosion hazard In these cases the vent should be piped away from the regulator t...

Page 4: ...le 2 Outlet pressure more than 2 psi 0 14 bar light diaphragm head or 3 psi 0 21 bar heavy diaphragm head above the setpoint may damage internal parts such as the diaphragm head and valve disk The maximum emergency casing outlet pressure is 15 psig 1 0 bar Startup caution Pressure gauges should always be used to monitor downstream pressure during startup Procedures used in putting this regulator i...

Page 5: ...pressure and relieving all internal pressure as described in Shutdown Regulators that have been disassembled for repair must be tested for proper operation before returned to service Only parts manufactured by Emerson Process Management Regulator Technologies Inc should be used for repairing Fisher regulators Relight pilot lights according to normal startup procedures Due to normal wear or damage ...

Page 6: ... tear the diaphragm when reassembling 6 Reassemble the spring case unit in the reverse order of the above steps Before tightening the cap screw or stem into the pusher post place the loosely assembled diaphragm and diaphragm head assembly into position in the lower casing being sure that the pusher post is hooked on the lever Rotate the diaphragm so that the diaphragm and lower casing holes are al...

Page 7: ... and S202 Series 7 Figure 5 Type S202 Regulator Assembly 50A9455 parts not shown 46 apply LUB SEA ADH section a a A A VENT 62 61 58 55 60 56 57 59 18 4 5 3 2 6 8 9 7 1 32 14 15 10 25 16 13 21 20 19 12 11 24 ...

Page 8: ... Management Regulator Technologies Inc USA Headquarters McKinney Texas 75069 1872 USA Tel 1 800 558 5853 Outside U S 1 972 548 3574 Asia Pacific Singapore Singapore 128461 Tel 65 6777 8211 Europe Bologna Italy 40013 Tel 39 051 4190611 Gallardon France 28320 Tel 33 0 2 37 33 47 00 TESCOM Emerson Process Management Tescom Corporation USA Headquarters Elk River Minnesota 55330 2445 USA Tel 1 763 241 ...

Reviews: