background image

8

Technical Specifications 

Alarm Configurations: 

Upper/lower/both/none, alerts are consecutive 

Calibration: 

Silicon based sensor is calibrated at the time of manufacture by 
Texas Instruments; NIST certificate of traceability available

Frequency:

US 915 MHz or EU 868 MHz

Housing: 

NEMA 6/IP67 dust and water resistant;  FDA 21 CFR compliant 
food-grade packaging

In-Use Life: 

Up to 60 days

 

Memory: 

4K EEPROM, 1922 hard data points

Operating Range: 

-20°C to 60°C (-4°F to 140°F)

Read Range: 

300 feet/91 meters (Line of Sight)

Recycle Options: 

GO GreenSense™ Program

Shelf Life:

8 months (6, 15 day loggers), 6 months (30, 60 day loggers)

Size:

2.4in x 3.3in (60mm x 84mm)

Start Delay: 

Standard 30 minutes

Temperature Accuracy: 

+/- 0.5°C typical between -20°C to 60°C(-4°F to 140°F)

Temperature Resolution: 

0.1°C

Temperature Sampling Frequency: 

One minute with five minutes average

Weight:

0.6 oz (17.0 g)

Lithium Battery Exception

Batteries utilized in GO Wireless Loggers are under the weight limit for lithium batteries 
on airplanes and qualify for an exemption under special provision 188 of §173.185(f) and 
§173.185 (g) (1) of the Hazardous Materials Regulations (HMR: 49 CFR Sections 171-180).

GO Wireless Loggers can be easily recycled through the GO GreenSense program. GO GreenSense 

is a recycling program that facilitates the return of Emerson temperature monitoring loggers for 
proper battery and component recycling. Through the GO GreenSense program, Emerson provides 
customers with eco-friendly return boxes and pre-paid postage return labels free of charge. Unlike 
bulky traditional temperature monitoring devices, customers can fit hundreds of temperature loggers 
in the provided medium-sized box. GO GreenSense takes the hassle out of returning loggers for 
recycling. For more information, email 

GOGreen@Emerson.com

 

or call +1-877-788-9299.

GO GreenSense™ Program

Summary of Contents for GO PSUWL01F

Page 1: ...GO Wireless Logger User Manual Cargo Monitoring Solutions ...

Page 2: ...ireless Logger Page 4 Operating Range Page 5 Activating GO Wireless Loggers Page 5 Logger Placement Scenarios Page 6 Regulatory Approvals Page 7 GO GreenSense Program Page 8 Lithium Battery Exemption Page 8 Technical Specifications Page 8 Technical Support Page 9 ...

Page 3: ...s do not require ongoing calibration to maintain accuracy Loggers have the capability to measure ambient air temperature and are also equipped to take a surface read of the object to which they are attached providing a more accurate assessment of actual product temperature With preprogramming functionality standard temperature range specifications can be set for the most frequently shipped perisha...

Page 4: ...mum of 3 seconds to activate LEDs will flash in a sequence to indicate successful activation Loggers should be activated when the product is ready to be monitored 5 Duration Indicates how many days under normal conditions the logger will collect data after it is activated 6 Part Number A unique alphanumeric identifier used to reference the type of logger and preprograming combination 7 Logger Uniq...

Page 5: ...ogger for 3 seconds green and amber LEDs will flash in a sequence to indicate successful activation Once the logger has been started time and temperature recording will begin recording wireless transmission will be enabled and the green LED will flash every 4 seconds Time and temperature recording cannot be disabled once started Apply the logger to product or product packaging Activating GO Wirele...

Page 6: ...the temperature fluctuations experienced within a container Carton Level Many customers with high value product where temperature specifications are critical may choose to use Emerson GO Wireless Loggers on each individual carton inside a master case Product Level Loggers are sealed in a plastic pouch and take surface reads of the object to which they are attached They can be placed in or laid dir...

Page 7: ...e at his own expense This equipment complies with FCC RF Exposure requirements and should be installed and operated with a minimum distance of 20 cm between the radiator and any part of the human body This device complies with Industry Canada licence exempt RSS standard s Operation is subject to the following two conditions 1 This device may not cause interference and 2 this device must accept any...

Page 8: ...inute with five minutes average Weight 0 6 oz 17 0 g Lithium Battery Exception Batteries utilized in GO Wireless Loggers are under the weight limit for lithium batteries on airplanes and qualify for an exemption under special provision 188 of 173 185 f and 173 185 g 1 of the Hazardous Materials Regulations HMR 49 CFR Sections 171 180 GO Wireless Loggers can be easily recycled through the GO GreenS...

Page 9: ...one of its affiliated companies 2019 Emerson Electric Co All rights reserved Technical Support Technical Support is available 24 hours a day 7 days a week We re with you every step of the way Toll Free 1 877 998 7299 Emerson com Cargo CargoSupport Emerson com Live Chat ...

Reviews: