18
19
ENGLISH
!
!
!
CARE AND USE
ADDITIONAL CONSIDERATION WHEN UTILIZING FILTRATION SYSTEM:
CAUTION: Electric Shock Hazard.
To prevent electrical shock, disconnect power before servicing unit. Use only a
properly earthed (grounded) and polarized electric outlet.
WARNING: Scalding Hazard.
Do not allow water to boil. May result in severe burns.
CAUTION: Personal Injury.
ADJUSTING THE THERMOSTAT
For ideal performance adjust the tank temperature to the setting two steps down
(approximately 205°F, 96°C) from the maximum setting. Turn the dial on front of the tank
clockwise or counter clockwise to raise or lower the water temperature. After adjusting, depress
or twist the dispenser handle for 20 seconds for water to re-heat to the new setting.
CLEANING THE DISPENSER AND TANK
SEASONAL STORAGE/DRAINAGE
Anytime the unit is not used for extended periods of time, unplug and drain unit. If it is below freezing you will
need to unplug the unit and drain it.
FILTER GUIDE AND REPLACEMENT
To reduce the risk of water leakage or flooding, and to ensure optimal filter performance:
Change the disposable filter cartridge; the disposable filter cartridge MUST be replaced every 6 months or sooner.
Replace filter cartridge when there is an obvious decrease in water flow to the dispenser or if there is an
objectionable taste or odor to the water.
Filter replacement instructions:
• Disconnect power from unit (unplug unit).
• Depress or twist hot water dispenser lever and allow
water to flow until it is cool.
• Shut the cold water dispenser off at the valve.
• Disconnect tubes from the tank.
• Unhook tank from wall.
• Hold tank upside down and drain the water
into the sink.
• Towel dry any water drippings from tank area.
• Reinstall tank to wall and reconnect tubes.
• Remove and discard filter cartridge,
if applicable.
• To put back into working order, install new filter
cartridge (if applicable) and turn on cold water supply
at valve. Depress or twist the hot water dispenser
faucet lever and hold until water flows from the spout.
Plug in the tank.
• Flush filter for 4 minutes, 3 gal (11.4 L) before first use for F-1000, F-2000.
• Recommended water flow: .75 gpm (2.84 Lpm)
• F-1000, F-2000 filter capacity: 500 gal (1,893 L)
• Only use mild cleaners to clean the dispenser and
plastic components.
• Cleaners with acids, abrasives, alkaline, and organic
solvents will result in deterioration of the plastic
components and void the warranty.
• Regularly check for signs of corrosion by
examining the appearance of the dispensed water
every three (3) months.
• If there is any discoloration or rusty appearance,
unplug and drain unit as described in the
Seasonal Storage/Drainage section on this page
of the manual.
• If the water discoloration remains after
draining and refilling unit, discontinue use
and contact InSinkErator.
• When the inlet and outlet ports have been
closed and the filter’s internal pressure has
been relieved, water about 1/4 cup (60ml) will
discharge from vent line.
• It is recommended that carbon filters be replaced
every 6 months.
• If the new filter cartridge cannot be inserted, insert
the old one and turn counterclockwise until it stops,
remove it and then retry the new cartridge.
1. Replace with an InSinkErator
®
filter.
2. Place pan or dish towel under the filter to catch
water drainage during change.
3. Slowly turn the cartridge counterclockwise
completely until it stops (1/4 turn).
4. Pull cartridge straight down and discard.
5. Insert new cartridge into filter head.
6. Top surface of cartridge will become flush with the
bottom of the filter head when fully engaged.
7. Turn the cartridge clockwise until it stops (1/4 turn).
8. Align the in/out arrow on the head and bracket
assembly to the in/out arrow on the cartridge.
9. Open dispenser to expel trapped air.
10. Run water for 4 minutes before usage.
Continuous boiling sounds
in the tank or water and
steam spits forcefully from
spout without turning on
the dispenser.
Water taste or odor.
Water is not hot.
New filter does not fit.
Water is too hot or not
hot enough.
Indicator lights on dial
on front of tank do not
illuminate.
The filter leaks.
Water comes out of the
vent instead of spout.
No water flow or low
water flow.
Water is dripping
from the spout/vent
intermittently.
Water is dripping
from the spout/vent
constantly.
Water discoloration/
rusty appearance.
Divided stream.
• Unit is boiling.
May be normal during initial set-up.
• Filter water flow direction is wrong.
• Filter needs to be flushed out.
• Life of filter has expired.
• The unit is unplugged.
• The electric outlet is inoperative.
• Head and bracket not fully rotated.
• Filter O-ring breach.
• Thermostat is not adjusted to
your needs.
• The unit may not be plugged in.
• The electric outlet is inoperative.
• Head and bracket not fully rotated.
• Filter O-ring breach.
• Outlet tube is blocked.
• Life of filter has expired.
• The expansion chamber is not
draining properly due to low water
pressure.
• The spout is blocked.
• Debris in the water line may be in
the dispenser valve seat, causing a
slow water leak.
• Corrosion of unit.
• Debris in the end piece.
• Depress or twist hot water dispenser handle to
release some water from the tank.
• Adjust water temperature by turning the dial on the
front counter clockwise.
• Remember that at higher altitudes, water boils at
lower temperatures.
• Review filter tube connection instructions.
• Depress or twist the dispenser and run until the water is cold.
• If there is no change, replace filter cartridge.
• Make sure the unit is connected to a correctly
earthed electric outlet.
• Make sure the circuit breaker or fuses are
functioning correctly.
• Check that the outlet is not switched off.
• Take out the new filter, put in old filter.
• Remove, inspect, reinstall filter cartridge.
• Adjust the thermostat, then depress or twist hot
water dispenser handle for 20 seconds to bring in
fresh water to be heated at the new setting. Allow
5-7 minutes for water to reach new temperature.
• Make sure that the circuit breaker or fuses are
functioning properly.
• Check that the outlet is not switched off.
• Test unit by reinstalling old filter and rotating to
full stop. Check for leaks.
• Check that outlet tube is not kinked, twisted
or pinched.
• Unscrew spout end piece and clean out any debris.
• Replace filter cartridge. See Care and Use section
of this manual.
• Unplug the unit. If the dripping does not stop after a
few minutes, check the supply valve to ensure that it
is fully open and there are no obstructions in the
water line reducing the pressure below 15 psi (103 kPa)
(ie, a poorly mounted saddle valve, a clogged water
filter or a partially opened shut-off valve).
• Unscrew spout end piece and clean out any debris.
• Unscrew spout end piece and clean out any debris.
• Depress or twist hot water dispenser handle 7-10
times to flush dispenser and lines.
• Unplug and drain unit as described in the Care
and Use section of this manual. If the water
discoloration remains after draining and refilling the
unit, discontinue use and contact InSinkErator.
• Unscrew spout end piece and clean out any debris.
TROUBLESHOOTING
PROBLEM
PROBLEM
POSSIBLE CAUSE
POSSIBLE CAUSE
WHAT TO DO
WHAT TO DO
FILTRATION ISSUES
The HWT200-F1000S is certified by IAPMO R&T
against NSF/ANSI Standard 42 for the reduction of
claims specified on the Performance Data Sheet The
HWT200 tank is certified against NSF/ANSI Standard
58 for materials safety only.