background image

Ensuring The High Availability
Of Mission-Critical Data And Applications.

While every precaution has been taken to ensure the accuracy and completeness of this literature, Liebert Corporation assumes 
no responsibility and disclaims all liability for damages resulting from use of this information or for any errors or omissions.
© 2010 Liebert Corporation
All rights reserved throughout the world. Specifications subject to change without notice.
® Liebert is the registered trademark of Liebert Corporation. 
All names referred to are trademarks or registered trademarks of their respective owners.

Locations

United States

1050 Dearborn Drive

P.O. Box 29186

Columbus, OH 43229

Europe

Via Leonardo Da Vinci 8

Zona Industriale Tognana

35028 Piove Di Sacco (PD) Italy

+39 049 9719 111

Fax: +39 049 5841 257

Asia

29/F, The Orient Square Building

F. Ortigas Jr. Road, Ortigas Center

Pasig City 1605

Philippines

+63 2 687 6615

Fax: +63 2 730 9572

The global leader in enabling 

Business-Critical Continuity

Emerson, 

Business-Critical Continuity

, Emerson Network Power and the Emerson Network Power logo are

trademarks and service marks of Emerson Electric Co. or one of its affiliated companies.

©2010 Emerson Electric Co.

AC Power

Connectivity 

DC Power

Infrastructure Management & 

Monitoring

Embedded Computing 

Embedded Power

Power Switching & Controls

Precision Cooling

Outside Plant

EmersonNetworkPower.com

Racks & Integrated Cabinets

Services

Surge Protection

Technical Support / Service
Web Site

www.liebert.com

Monitoring

liebert.monitoring@emerson.com
800-222-5877
Outside North America: +00800 1155 4499

Single-Phase UPS & Server Cabinets

liebert.upstech@emerson.com
800-222-5877
Outside North America: +00800 1155 4499

Three-Phase UPS & Power Systems

800-543-2378
Outside North America: 614-841-6598

Environmental Systems

800-543-2778
Outside the United States: 614-888-0246

Emerson Network Power.

  

SL-23211_REV0_09-10

Summary of Contents for Liebert IntelliSlot IS-RELAY

Page 1: ...ntelliSlot Relay Card User Manual Проконсультироваться и купить данное оборудование вы можете в компании АНД Системс адрес 125480 г Москва ул Туристская д 33 1 site https andpro ru тел 7 495 545 4870 email info andpro ru При обращении используйте промокод AND PDF и получите скидку ...

Page 2: ...t 1 2 0 INSTALLATION 2 Required Parts and Tools 2 Instructions 2 3 0 PIN CONFIGURATION 4 4 0 JUMPER SETUP 5 Figures Figure 1 Pin location and numbering 4 Figure 2 Jumper location and numbering 5 Tables Table 1 Relay card pin configuration 4 Table 2 Jumper connections 5 ...

Page 3: ...upported units the inverter shut off command can be controlled from the computer directly connected to the UPS via the factory installed DB9 connector and will conserve battery power after the workstation shutdown is completed The Liebert IntelliSlot Relay Card is rated for 24VAC VDC at 1A Inspecting Shipment on Receipt Upon accepting shipment inspect the packaging and product for any damaged or m...

Page 4: ...ort location and orientation 3 Remove the two retaining screws from the Liebert IntelliSlot port cover plate on the unit Save the screws for reassembly in Step 5 4 As you insert the card make sure the holes are aligned with those on the UPS Initially the card should slide in freely as you carefully align screw holes As you feel it click into place press firmly to ensure solid seating in the slot 5...

Page 5: ...nes for terminal block specifications Proceed to the following sections 3 0 Pin Configuration to configure the terminal blocks 4 0 Jumper Setup to configure the jumpers Acceptable Wire Size Wire Strip Length 24 16 AWG 0 24 0 28 in 6 7mm ...

Page 6: ...urs 3 Low Battery Closed if battery is OK 4 Common UPS Fault 5 UPS Fault Closed if UPS fault occurs 6 UPS Fault Closed if no UPS failure 7 Common On Battery 8 On Battery Closed if On Battery power Utility failure 9 On Battery Closed if not On Battery power Utility OK 10 Signal Ground Use for UPS Any Mode Shutdown 11 Signal Ground Use for UPS Any Mode Shutdown 12 UPS Any Mode Shutdown Turn UPS outp...

Page 7: ...able 2 allowing relay commons to be tied together NOTE The jumpers should be removed if there is any external volt age source that may intentionally or inadvertently be connected to the relay Removing the shunt from any two pins breaks the connection between the relay commons so they are not tied together Table 2 Jumper connections Jumper Relay P6 On Battery P5 UPS Fault P4 Low Battery P3 On Bypas...

Page 8: ...r Road Ortigas Center Pasig City 1605 Philippines 63 2 687 6615 Fax 63 2 730 9572 The global leader in enabling Business Critical Continuity Emerson Business Critical Continuity Emerson Network Power and the Emerson Network Power logo are trademarks and service marks of Emerson Electric Co or one of its affiliated companies 2010 Emerson Electric Co AC Power Connectivity DC Power Infrastructure Man...

Reviews: