background image

5. Slide the guide plate(5) up the light

fitter’s threaded nipple until the glass
shade(1) mates with the bottom of the
light fitter plate (Figure 6).

6. Install the hex nut onto the threaded

nipple and firmly hand tighten the nut to
secure the guide plate(5) and glass
shade(1) onto the light fitter(2).

7. Slide the fan switch chain(3) through

the side hole of the glass cap and slide
the light fitter chain(4) through the
center hole of the glass cap(6). Slide
the glass cap(6) up the threaded nipple
until it rests against the bottom of the
glass shade(1) (Figure 6).

8. Pass the light fitter chain(4) through the

center of the finial nut and fasten the
finial nut(7) onto the fitter nipple. Gently
hand tighten the finial nut(7) up against
the bottom of the glass cap(6) to secure
it in position (Figure 6).

9. Reinstall the fan switch pendant(8) to

the fan switch chain(3) (Figure 6).

10. Installation is now complete. Turn on

the electricity at the main fuse or
circuit breaker box.

5

4

11. Position the cup/light fitter(1)(7) on

the cover plate(2) and install the
three screws(3) that were previously
removed in Step 2 and tighten
securely.

12. Proceed to “Installation of

Fluorescent Bulbs and Glass Shade”
section.

Installation on Emerson

Fans Having Two-Piece

Die-Cast Switch

Housings

1. Remove all parts and parts packages

from carton.

2. Remove the cover(5) from the fan

switch housing(1) by removing the two
outer screws(2). (See Figure 4).

3. Remove the center screw(4) from the

cover(5). Insert the black and white
wires from the light fitter(6) thru the
hole and thread the switch housing
cover tightly onto the light fitter.

4. Insert the black and white wires through

the lockwasher(8) and hex nut(7)
supplied. Firmly tighten the hex nut to
secure the light fitter to the switch
housing cover(5).

(3) WIRE
      CONNECTORS

WHITE WIRES

BLUE WIRE

BLACK WIRE

FAN SWITCH
CHAIN

(1) SWITCH
      HOUSING
      ASSEMBLY

(5) COVER

(2) SCREWS

(4) CENTER 
      SCREW

(8) LOCKWASHER

(7) HEX NUT

(6) LIGHT FITTER

Figure 4

To avoid possible fire or electric shock,
be careful not to pinch wires between
switch cup and the cover plate.

WARNING

!

To avoid possible electric shock, be sure
electricity is turned off at the main fuse
or circuit breaker box before wiring.

WARNING

!

5. Carefully locate the white and blue

wires (labeled either “L” or “LIGHT”) in
the switch housing. Remove and retain
the wire connectors(3) from the wires.

6. Connect the white wire from the ceiling

fan to the white wire of the light fitter(6).
Connect the blue wire from the ceiling
fan to the black wire of the light fitter.
Use U.L. listed wire connectors(3)
(previously removed in Step 5) to make
connections. (Figures 3 and 4.)

7. Carefully tuck all wires and splices into

the switch housing(1).

8. Attach the cover/light fitter(5)(6) to the

switch assembly housing(1) using the
two outer screws(2) that were removed
in Step 2) (Figure 4.)

9. Proceed to “Installation of Fluorescent

Bulbs and Glass Shade” section.

To avoid fire or electrical shock, be
careful not to pinch wires between
the switch housing assembly and
the cover.

WARNING

!

Installation of

Fluorescent Bulbs and

Glass Shade

1. Carefully position one of the GU24

fluorescent bulbs(1) (supplied) into the
light fitter socket. Twist the bulb
clockwise, approximately 1/16 turn, to
engage the bulbs pins into the light
fitter socket holes(2) (Figure 5). Install
the remaining three GU24 fluorescent
bulbs in the same manner.

2. Remove the fan switch pendant(3) from

the fan switch chain(4) for installation of
glass. Place the fan switch chain
through the light fitter plate(5) hole
(Figure 5).

3. Place glass shade (1) onto light fitter(2)

making sure that both fan switch
chain(3) and light fitter chain(4) are
positioned through the center hole in
glass shade(1) (Figure 6).

4. Slide the switch chain(3) through the

side hole of the guide plate(5) and the
light fitter chain(4) through the center
hole of the guide plate(5) (Figure 6).

To avoid fire hazard, do not exceed
wattage indicated on the fixture.

WARNING

!

THREADED 
NIPPLE

(2) LIGHT FITTER

13-WATT GU24 
FLUORESCENT BULB

(1) GLASS
SHADE

(3) FAN SWITCH 
CHAIN

(4) LIGHT FITTER 
CHAIN

(5) GUIDE PLATE

(8) FAN SWITCH 
PENDANT

(7) FINIAL NUT

(9) LIGHT SWITCH 
PENDANT/COUPLING

(6) GLASS CAP

HEX NUT

LIGHT FITTER 
PLATE

Figure 6

(1) 13-WATT GU24 
FLUORESCENT BULB (4)

(2) LIGHT FITTER 
SOCKET

(5) LIGHT FITTER 
PLATE HOLES

(4) FAN SWITCH 
CHAIN

(3) FAN SWITCH 
PENDANT

LIGHT FITTER 
PLATE

Figure 5

Summary of Contents for LK59FOM

Page 1: ...e center Your Emerson Light Fixture should be properly packed to avoid damage in transit since we will not be responsible for any such damage What Is Not Covered This warranty also does not cover any defects malfunctions or failures caused by Repairs by persons not authorized by Emerson Electric Co Use of parts or accessories not authorized by Emerson Electric Co Mishandling improper installation ...

Page 2: ...re electricity is turned off at the main fuse or circuit breaker box before wiring 2 Make certain no bare wires are exposed outside the wire connectors 3 All wiring must conform to national and local electrical codes 4 Follow the recommended instructions for the proper method of wiring your new light fixture If you feel you do not have enough electrical wiring knowledge or experience have your lig...

Page 3: ...m twisting Figure 2 Figure 3 To avoid possible fire or electrical shock make certain no bare wire strands are exposed outside wire connectors WARNING NOTE This equipment has been tested and found to comply with part 18 of the FCC Rules This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interferenc...

Page 4: ...RNING To avoid possible electric shock be sure electricity is turned off at the main fuse or circuit breaker box before wiring WARNING 5 Carefully locate the white and blue wires labeled either L or LIGHT in the switch housing Remove and retain the wire connectors 3 from the wires 6 Connect the white wire from the ceiling fan to the white wire of the light fitter 6 Connect the blue wire from the c...

Reviews: