Parameter
Specifications
Power factor
Rectifier –48 V dc, 750 W:
>0.99 from 40% to 100% load at 120 V ac
>0.90 from 40% to 100% load at 240 V ac
>0.94 from 60% to 100% load at 240 V ac
>0.97 at 100% load at 240 V ac
Rectifier –48 V dc, 1500 W:
>0.98 from 50% to 100% load at 208 V ac
>0.97 from 50% to 100% load at 240 V ac
>0.99 from 80% to 100% load at 208 V ac and 240 V ac
Total Harmonic
Distortion (THD)
Rectifier –48 V dc, 750 W:
<15% from 50% to 100% load at 208 V ac and 240 V ac
<6% from 50% to 100% load at 120 V ac
Rectifier –48 V dc, 1500 W:
<10% from 50% to 100% load at 208 V ac and 240 V ac
<5% from 50% to 100% load at 120 V ac
Output noise
<10 mV rms in 3 kHz bands from 10 kHz to 20 MHz.
Operating
temperature
Rectifier –48 V dc, 750 W: Normal operation from –40
°
C (–40
°
F )
to 75
°
C (167
°
F).
Rectifier –48 V dc, 1500 W: Normal operation from –40
°
C (–40
°
F )
to 65
°
C (149
°
F); output power is linearly derated from 1500 W to
0 W between 65
°
C (149
°
F) and 75
°
C (167
°
F).
Heat dissipation Rectifier –48 V dc, 750 W: 74.1 W (253 Btu/hr) at 750 W output,
230 V ac input, 93 W (318 Btu/hr) at 120 V ac
Rectifier –48 V dc, 1500 W: 148.3 W (506.5 Btu/hr) at 1500 W
output, 230 V ac input
Note:
Although the rectifiers and the System Manager CIP can operate on
an individual basis at temperatures between 65
°
C (149
°
F) and 75
°
C
(167
°
F), and this for limited periods of time and/or derating, 65
°
C (149
°
F)
is the maximum operating temperature at the system’ level.
3.2.5.
Distribution and battery connection section
3.2.5.1. Distribution section
Note:
For an AP5C55BF Lorain CIP power shelf, refer to the SLC-96 or
Series-5 application Method of procedure for the distribution cabling
specifics applying to these (see section 1.6 for MOP number).
The distribution of the Lorain CIP
power shelves provides configuration
flexibility. It can be equipped either with:
•
up to six bullet-type single-pole circuit breakers in capacities from 1 to
100 A or fuses in capacities from 1 to 50 A, or
•
up to three bullet-type single-pole circuit breakers in capacities from 1
to 100 A or fuses in capacities from 1 to 50 A, and one 10-position
(SAN-O) fuse kit for fuses in capacities from 0.180 to 20 A or 8-
position (GMT) fuse kit for fuses in capacities from 0.180 to 15 A, or
Summary of Contents for Lorain CIP 48120 AP6C55CA