background image

7

emersonfans.com

Please contact 1-800-654-3545 for further assistance

U.L. Model No.: CF2000

AT LEAST

7'

FLOOR

CEILING

Figure 6

TWO SCREWS
SUPPLIED WITH
OUTLET BOX

HANGER
BRACKET

TAB

OUTLET
BOX

Figure 7

OUTLET
BOX

HANGER
BRACKET

HANGER BALL/
DOWNROD  
ASSEMBLY

NOTE: CEILING COVER, SUPPLY WIRES AND FAN WIRES 
OMITTED FOR CLARITY.

Figure 8

How to Hang Your Ceiling Fan

The outlet box and joist must be securely mounted and
capable of supporting at least 50 lbs. Use only a U.L.
outlet box listed as “Acceptable for Fan Support of
22.7kg. (50 lbs.) or less”.

WARNING

!

Failure to seat tab in groove could cause damage to
electrical wires and possible shock or fire hazard.

WARNING

!

To avoid possible fire or shock, do not pinch wires
between the hanger ball/downrod assembly and
hanger bracket.

WARNING

!

To reduce the risk of fire, electric shock, or personal
injury, mount fan to outlet box marked “Acceptable for
Fan Support of 22.7kg. (50 lbs.) or less”, and use
screws supplied with outlet box. Most outlet boxes
commonly used for support of light fixtures are not
acceptable for fan support and may need to be
replaced. Consult a qualified electrician if in doubt.

WARNING

!

The fan must be hung with at least 7' of clearance from
floor to blades (Figure 6).

WARNING

!

1.

Securely attach the hanger bracket to the outlet box
using the two screws supplied with the outlet box.
(Figure 7.)

2.

Carefully lift the fan and seat the hanger ball/
downrod assembly on the hanger bracket that was
just attached to the outlet box (Figure 8). Be sure the
groove in the ball is lined up with tab on the hanger
bracket (Figure 7).

Hanger bracket must seat firmly against outlet box. If
the outlet box is recessed, remove wall board until
bracket contacts box. If bracket and/or outlet box are
not securely attached, the fan could wobble or fall.

WARNING

!

NOTE: For ease of installation, first the fan motor and
housing assembly is installed on the ceiling. Then
after wiring of the fan is completed, the fan blade
assemblies will be attached to the motor hub.

Summary of Contents for MAUI BAY CF2000AB02

Page 1: ...Damp Location Ceiling Fan Owner s Manual Model Numbers CF2000AB02 Antique Brass CF2000AP02 Antique Pewter CF2000ORB02 Oil Rubbed Bronze Net Weight 26 0 Lbs 1 800 654 3545 www emersonfans com Questions problems missing parts Before returning to the store call Emerson Electric Customer Service 8 a m 6 p m EST Monday Friday ...

Page 2: ...an blade clearance for an 8 foot ceiling 5 The fan must be mounted with the fan blades at least 7 feet from the floor to prevent accidental contact with the fan blades 6 Follow the recommended instructions for the proper method of wiring your ceiling fan If you do not know enough about electrical wiring have your fan installed by a licensed electrician WARNING To reduce the risk of electrical shoc...

Page 3: ... retailer or catalog outlet for replacement before proceeding NOTE Fan blades are ordered separately and are packaged in separate carton 2 Remove the fan assembly from the protective plastic bag Place the fan assembly into the upper foam pad with the top of the motor facing up The upper foam pad serves as a holder for the fan during the first stages of assembly A B G E F C D PACKAGE CONTENTS 1 8 7...

Page 4: ...capable of withstanding a load of at least 50 pounds To reduce the risk of fire electric shock or personal injury mount fan to outlet box marked Acceptable for Fan Support of 22 7kg 50 lbs or less and use screws supplied with outlet box Most outlet boxes commonly used for support of light fixtures are not acceptable for fan support and may need to be replaced Consult a qualified electrician if in ...

Page 5: ...evis pin must go through the holes in the motor coupling and the holes in the downrod Push the straight leg of the hairpin clip through the hole near the end of the clevis pin until the curved portion of the hairpin clip snaps around the clevis pin The hairpin clip must be properly installed to prevent the clevis pin from working loose Pull on the hanger ball to make sure the clevis pin is properl...

Page 6: ...ide the hanger ball up the downrod aligning the ball so the pin is captured in the groove in the top of the hanger ball Pull the hanger ball up tight against the pin and securely tighten the setscrew in the hanger ball A loose setscrew could create fan wobble 9 The fan comes with blue black and white leads that are 80 long Before installing fan measure up approximately 6 to 9 inches above the ball...

Page 7: ...Support of 22 7kg 50 lbs or less and use screws supplied with outlet box Most outlet boxes commonly used for support of light fixtures are not acceptable for fan support and may need to be replaced Consult a qualified electrician if in doubt WARNING The fan must be hung with at least 7 of clearance from floor to blades Figure 6 WARNING 1 Securely attach the hanger bracket to the outlet box using t...

Page 8: ... using wire connector supplied Figure 9 After connections have been made turn leads upward and carefully push leads into the outlet box with the white and green leads on one side of the outlet box and the black and blue leads on the other side of the outlet box Check to see that all connections are tight including ground and that no bare wire is visible at the wire connectors except for the ground...

Page 9: ... in a clockwise sequence Failure to follow this procedure could result in fan wobble This completes the blade installation 4 Slip the pull chain through the bushing in the switch housing cover Position the switch housing cover on the switch housing and secure using two 8 32 x 3 8 screws supplied Figure 13 Secure the pendant supplied to the pull chain using the connector supplied Fan Blade Installa...

Page 10: ...aning use only a soft brush or lint free cloth to avoid scratching the finish Abrasive cleaning agents are not required and should be avoided to prevent damage to finish Maintenance SPEED CONTROL PULL CHAIN SWITCH REVERSING SWITCH Figure 14 1 Restore electrical power to the outlet box by turning the electricity on at the main fuse box 2 Check the operation of the fan by gently pulling on the 4 pos...

Page 11: ...ing excessively 2 Setscrew in hanger ball downrod assembly is 2 Tighten the setscrew in the hanger ball downrod assembly loose 3 Screws securing fan blade flanges to motor are 3 Check to be sure screws which attach the fan blade flanges loose to the motor are tight 4 Fan blade flanges not seated properly 4 Check to be sure the fan blade flanges seat firmly and uniformly to the surface of the motor...

Page 12: ...12 U L Model No CF2000 Repair Parts 7 1 2 14 15 3 18 16 17 19 25 10 26 28 5 4 23 29 6 13 18 9 8 22 21 17 12 20 27 30 11 24 31 ...

Page 13: ...92 762392 762392 4 Pin Clevis 1 5 Clip Hairpin 1 11 Coupling 1 12 Pendant 1 14 Wire Connector 3 15 Wrench Setscrew 1 16 Stud Threaded 1 1 4 2 17 Lockwasher 4 18 Knob Knurled 4 19 Screw 10 32 x 5 8 11 20 Screw 8 32 x 3 8 2 21 Screw 10 32 x 3 8 21 22 Washer Flat 21 29 Setscrew Hex Socket 1 30 Stud Threaded 1 2 6 Ceiling Canopy 761620 AB 761620 AP 761620 ORB 7 Hub Rubber 760601 760601 760601 8 Blade ...

Page 14: ...14 U L Model No CF2000 Notes ...

Page 15: ...s limited warranty You can return your Emerson Ceiling Fan to your place of purchase or you can call Emerson Customer Service at 1 800 237 6511 to obtain a return authorization and service identification tag In order for us to confirm that your Emerson Ceiling Fan is still under warranty please retain your receipt or other proof of purchase and have that information readily available when returnin...

Page 16: ... Service 8 a m 6 p m EST Monday Friday 1 800 654 3545 www emersonfans com Retain this manual for future use Air Comfort Products DIVISION OF EMERSON ELECTRIC CO 8100 W Florissant St Louis MO 63136 Part No F40BP73230002 Form No BP7323 2 Revision 130605 U L Model No CF2000 Printed in China 06 13 ...

Reviews: