Installation Manual
21
Wiring
suitable for use in the gland when using cable whose shield consists of foil and not
a braid. Go to Step 3.
•
If you are using armored cable, prepare the cable as described in Step 6, but do
not apply heat shrink – omit Step 6d, e, f, and g. Go to Step 3.
3. Identify the components shown in
Figure 2-1
.
4. Remove the core processor lid.
5. Slide the gland nut and the clamping insert over the cable. See
Figure 3-11
.
Figure 3-11: Gland nut and clamping insert
6. For connection at the core processor housing, prepare shielded cable as follows (for
armored cable, omit steps d, e, f, and g):
a. Strip 4 1/2 inches (114 mm) of cable jacket.
b. Remove the clear wrap that is inside the cable jacket, and remove the filler material
between the wires.
c. Remove the foil shield that is around the insulated wires, leaving 3/4 inch (19 mm)
of foil or braid and drain wires exposed, and separate the wires.
d. Wrap the shield drain wires around the exposed foil twice. See
Figure 3-12
. Cut off
the excess wire.
4 1/2 in
(114 mm)
3/4 in
(19 mm)
7/8 in
(22 mm)
7/8 in
(22 mm)
Shielded heat shrink
Gland body
Gland nut
Gland clamping
insert