background image

Using Your Humidifier

Step 1

Be sure unit is full of water and plugged in.

Step 2

Set air flow control        to desired setting.

Step 3

Set Humidity Control        to medium position
(half way between     and        )

NOTE:

Humidifier should operate with humid-

ity control on the recommended medium set-
ting. If it does not, the humidity is at a rela-
tively high level. To test the unit under this
condition, turn Humidity Control all the way
clockwise and unit should begin to operate.
After the unit has been tested, set Humidity
Control to about medium or desired level.

Allow 24 to 48 hours for humidifier to adjust.

If humidity level in home is sufficient, the
humidifier will only operate with Humidity
Control turned all the way clockwise.

IMPORTANT: Water damage may result if
condensation starts to form on windows
or walls. Humidity Control setting should
be lowered until condensation no longer
forms.

R

el

.H

u

m

id

it

y

Rel. H

umidity

R

el.

H

u

m

id

ity

MAX

MIN

1. Position the humidifier at least 2 inches

from any wall and away from any heat reg-
isters.

2. Do not restrict airflow from entering or exit-

ing the humidifier.

3. Use liquid EPA Registered Bacteriostat to

retard bacteria growth that may cause
odors and may be harmful to your health.

4. Regular cleaning as instructed in

“Cleaning Your Humidifier” section of this
manual is recommended.

5. Replace the evaporative wicking filters at

least once per humidification season or
more depending on water conditions in
your area.

Operating Tips for Best Performance

Relative Humidity

8

Step 4

If humidifier stops running and the amber Fill
Light     is not illuminated, the green desired
humidity light will illuminate. This means the
humidity level is at the normal requirements
for that setting or it is adjusting to the home
conditions. The table below shows recom-
mended indoor humidity levels. The figure
below shows approximate relative humidity
percentages which correspond to the various
settings of the Humidity Control.

-10° F

2° F

10° F

20° F*

-24° C
-18° C
-12° C
-6° C*

20%
25%
30%
35%

When Outdoor Recommended Indoor 

Temperature is:

Relative Humidity is:

* and above

SP6551 manual - 71238  7/12/05  1:56 PM  Page 8

Summary of Contents for MoistAIR HD1405

Page 1: ... Canada CAUTION READ ALL INSTRUCTIONS CAREFULLY BEFORE INSTALLATION SAVE THIS OWNER S MANUAL FOR FUTURE REFERENCE Model No HD14050 HD1405 Evaporative Console Humidifier Owner s Manual SP6551 manual 71238 7 12 05 1 56 PM Page 1 ...

Page 2: ...AL SAFETY INSTRUCTIONS 2 Limited Warranty All products covered by this Owner s Manual are warranted against defects in workmanship and materials for one year from the date of sale except for motors which are warranted for two years This warranty does not apply to damage from accident misuse or alteration nor where the connected voltage is more than 5 above the nameplate voltage nor to the equipmen...

Page 3: ...S Gallons 2 3 8 Gallons Each Capacity of Bottles Litres 9 Litres Each Sq Ft Coverage 2 900 Fan Speeds 3 Number of Filters 4 Pack HDC 12 or HDC12C Fill Light Indicator Yes Desired Humidity Indicator Yes Auto Humidistat Yes Auto Shut Off Yes Manual Dryout Yes See Page 7 Controls Rotary CUL Listed Yes Volts 120 A C Hertz 60 Amps 2 88 Watts 165 Based on an area with average insulation and an 8 foot ce...

Page 4: ...midified Air is Then Released Through the Top Dry Air Enters Through the Rear CAUTION Keep your humidifier clean While humidifiers do not cause colds some studies suggest that dirty humidi fiers can cause cold like symptoms in some people To avoid this clean your humidifier weekly with cleaners specifi cally recommended for evaporative humidifiers Unpacking Assembly Your new Emerson humidifier is ...

Page 5: ...tioned in another location Location Instructions Water Fill WARNING To reduce the risk of shock always unplug humidifier before filling cleaning or servicing WARNING To reduce the risk of fire or shock hazard do not pour or spill water into control or motor area Close the control cover If controls get wet let them dry completely and have unit checked by authorized service person nel before pluggin...

Page 6: ...ten only Check for possible leaks by performing the following 1 Grasp bottle handle and hold the bottle upright over a sink 2 Press up on valve cap plunger for about one second to let out a little water 3 Release the plunger 4 Listen for air bubbles Look for leaks around Side Fill Cap 5 If you hear air bubbles or see leaks retighten Side Fill Cap and repeat steps 1 4 NOTE Repeat for other bottle I...

Page 7: ...en more humidity is called for the fans will turn on and the light will go out Air Flow Control The unit is adjusted from OFF to high with a three speed rotary control The higher the air flow speed the more water is evaporated and released into the air Low speed is the quietest and is provided for conditions that may not require as high an evaporation rate Fill Light When the unit has a small amou...

Page 8: ...difier at least 2 inches from any wall and away from any heat reg isters 2 Do not restrict airflow from entering or exit ing the humidifier 3 Use liquid EPA Registered Bacteriostat to retard bacteria growth that may cause odors and may be harmful to your health 4 Regular cleaning as instructed in Cleaning Your Humidifier section of this manual is recommended 5 Replace the evaporative wicking filte...

Page 9: ...overings are not susceptible to water damage i e kitchen or bath areas 2 Open the pivoting lid and remove water bottles and set aside Grasp the fan assembly front center and rear center Lift off and set aside on a clean flat surface The filter assemblies are now accessible 3 Lift filter housings out of cabinet and place where you may work on them comfortably With a soft absorbent cloth remove any ...

Page 10: ...e that spring tabs of filter hous ings are towards front of cabinet Align the lower portion of the filter assembly over the six ribs located at the bottom rear of the humidifier cabi net f Position fan assembly onto the cabinet Make sure the fan venturi lowest cylin der section below the fan is placed inside the filter housing g Replace water bottles h Close the pivoting lid on the fan assembly i ...

Page 11: ...nter Lift off and set aside on a clean flat surface The filter housings are now accessible b Before removing the internal parts of the humidifier cabinet we recommend moving the humidifier to an area where floor cov erings are not susceptible to water dam age i e kitchen or bath area Lift the filter housing assemblies out of the cabinet and set to the side c Remove the water level float from the h...

Page 12: ...allon of water Let solution stay 20 minutes swishing every few minutes Wet all surfaces normally exposed to water 2 Empty humidifier cabinet after 20 min utes Rinse with water until bleach smell is gone Allow unit to dry out completely 3 Water bottles should be cleaned in same manner End of Season Maintenance 1 Follow bi weekly maintenance instructions at end of humidification season 2 Remove and ...

Page 13: ... continue to empty A small amount of water in cabinet and fill light is on REMEDY Check 120 volt power source Turn speed control clockwise Raise humidistat setting if desired Free float from obstruction Slide float retainer down to lowest position in slot at back of cabinet See diagram on page 11 Change to fresh filters The humidifier is designed so the right bottle empties first Continue to run u...

Page 14: ... Parts Parts List for MoistAir Humidifier Model No HD14050 28 27 26 25 24 23 28 27 21 26 30 24 23 22 21 20 19 18 14 15 13 31 12 11 33 16 17 3 1 32 8 10 7 5 4 6 9 34 2 SP6551 manual 71238 7 12 05 1 56 PM Page 14 ...

Page 15: ... 20 823726 Rail Kick 21 Screw Pan Hd Ty AB 10 x 3 4 22 828515 Caster Twin Wheel 23 823849 Support Filter Lower 24 HDC 12 or Filter Evaporative USA HDC12C Filter Evaporative Canada 25 828197 Support Upper Filter 26 828534 Support Motor 27 828115 1 Motor Includes mounting hardware 28 822406 1 Fan 30 828197 Support Upper Filter 31 824120 Cord w Plug 32 826367 Retainer Micro Switch 33 Screw Pan Hd Typ...

Page 16: ...11 04 FOR TECHNICAL HELP CALL 800 654 3545 FROM USA OR 888 744 4687 FROM CANADA Please have complete model number Emerson Tool Company For more information about MoistAir humidifiers visit our website at www moistair com SP6551 manual 71238 7 12 05 1 56 PM Page 16 ...

Reviews: