INSTALLATION
AXPTC125 POWER TEE SPLICE CONNECTION KIT
INSTRUCTIONS
TULSA, OK 74146
TEL 918-627-5530
FAX 918-641-7336
www.nelsonheaters.com
GA-5052 Rev. 3 DRAFT
Sheet 5 of 10
August 2017
Lightly cut around the cable outer jacket and up
the center.
Bend cable to break outer jacket.
Remove outer jacket from heating cable.
Trim excess braid up to the heating cable
jackets.
Make a diagonal cut between bus wires.
Pinch end termination body and fill void with
silicone adhesive.
Push termination firmly onto heating cable.
½” (13 mm)
1
2
3
4
5
6
Slide green/yellow tubing over braid.
Trim bus wires and braid as necessary.
½” (13 mm)
END TERMINATION INSTALLATION
5
POWER TERMINATION INSTALLATION
WARNING
Do not megger or hipot until silicone completely
cured.
Braid must be kept from bus wires or shorting may
occur.
Note: The end seal is limited to exposure temperatures of 375
o
F (191
o
C).
The HEC100 or HEL100 kits can be used to terminate the cable off the pipe
in higher exposure temperature situations