SAG582127000
System Application Guide
Issue AF, February 26, 2014
Spec. No. 582127000 (Model 721
NPBB
)
Page 18 of 125
This document is property of Emerson Network Power, Energy Systems, North America, Inc. and contains confidential and proprietary information owned by Emerson Network Power, Energy
Systems, North America, Inc. Any copying, use, or disclosure of it without the written permission of Emerson Network Power, Energy Systems, North America, Inc. is strictly prohibited.
3) 588705000 Rectifier Option: Order interface components for module mounting shelf(s) Spec.
No. 588705000 as required per List
. Order field expansion module mounting shelf(s) per List
. Order module mounting shelf(s) per PD588705000 (choices are 58870500021, 58870500022,
58870500031, 58870500032).
a) Order the front access AC Input Termination Assembly per List
, or
58870500021 ordered (or order module mounting shelves with AC line cords or terminal blocks,
58870500022, 58870500031, 58870500032).
b) Order rectifier modules as required, P/N
, or
c) Order a module mounting position blank cover panel, P/N 21140440, for each empty module
mounting position in the system, as desired.
4) 588705000 Converter Option: Order interface components for module mounting shelf(s) Spec. No.
588705000 as required per List
. Order field expansion module mounting shelf(s) per List
. Order
module mounting shelf(s) per PD588705000 (choices are 58870500040, 58870500041, 58870500042).
a) Order the front access DC Input Termination Assembly per List
, or
58870500040 ordered (or order module mounting shelves with terminal blocks, 58870500041,
58870500042).
b) Order converter modules as required, P/N
c) Order a module mounting position blank cover panel, P/N 21140440, for each empty module
mounting position in the system, as desired.
5) 588705300 Rectifier/Converter Option: Order interface components for module mounting shelf(s) Spec.
No. 588705300 as required per List
. Order field expansion module mounting shelf(s) per List
Order module mounting shelf(s) per PD588705300.
a) Order the front access AC Input Termination Assembly per List
, or
mounting shelves with AC input cable assemblies, see PD588705300).
b) Order rectifier modules as required, P/N
c) Order optional converter interface components per List
d) Order optional DC-DC converter modules as required, P/N
6) Order battery trays as required per List
a) Order batteries as required per “
” under ACCESSORY DESCRIPTIONS.
b) Order “
Optional Battery Tray Battery Disconnect Circuit Breaker and Housing Kits
” as required.
c) Order “
Optional Battery Tray Front Battery Cover Kits
” as required.
List 21: One-Row Distribution Cabinet
Features
♦
Accepts one (1) distribution panel.
♦
Rated for up to 600 amperes of distribution.
Restrictions
For use in
if it is to be used with a
and
bays (no interbay busbar landings available).
Battery disconnect panels cannot be ordered for use in a List 21.
Ordering Notes
1) Order one (1) distribution panel as required per “
Single Voltage Distribution Panel
” under LIST DESCRIPTIONS.
2) Order fuses and/or circuit breakers as required per “
” under ACCESSORY
DESCRIPTIONS.
3) Order input and load distribution lugs, lug adapters, and lug hardware kits as required per “
under ACCESSORY DESCRIPTIONS.