HIGH_CASE_TEMP_RESET
0: No effect
1: Reset high
case
temperature
0
Enumerated
This parameter is used to request the
parameter CASE_TEMP_MAX be reset to
the current internal case temperature.
Setting this parameter at a value of 1 will
cause the transmitter to reset the
CASE_TEMP_MAX value. The transmitter
will set this parameter to 0 once it has
completed this process.
39
IO_PIN_MODE
See table 2
Enumerated
This parameter represents the operating
mode of the discrete IO pin of the transmitter.
0 = Alarm Contact Mode, 1=Calibration
Sequence Mode.
40
IO_PIN_STATE
0: Off
1: On
Enumerated
This parameter represents the current state
of the transmitters discrete IO pin.
0 = FALSE, 1 = TRUE.
41
MODE_BLK
See Function Block Specification, part 1.
FF-890, page 50.
5
O2_PERCENT_OF_RANGE
0.0-100.0
%
This is the percent of total range value.
15
O2_RANGE
0-40
% O2
This contains the upper and lower % O2
range values, the units, and the precision.
16
OXY_BLOCK_ALARM
See section 4.7
in FF-903
0
Enumerated
This is the FF block alarm code. See
Transducer Blocks, part 2. FF-903, page 41.
53
OXY_BLOCK_ERR
See table 3
0
Enumerated
This is the Oxymitter's device alarm code.
See Table 3.
52
PRIMARY_VALUE
(O2_VALUE)
0.0-25.0
% O2
This is the value that should appear on the
output channel of the transducer block. In the
Oxymitter, this is the present % O2 reading
and should reflect any test gas being applied.
13
PRIMARY_VALUE_TYPE
See section 4.1
in FF-903
0
Enumerated
Selected from list in Transducer Block
Specification, part 2. FF-903, page 39,
section 4.1.
14
SECONDARY_VALUE
-10000 - 10000
o
C
See Transducer Block Specification, part 2.
FF-903, page 37. In the Oxymitter, this is the
temperature of the electronics.
49
SECONDARY_VALUE_
UNITS
See Transducer Block Specification, part 2.
FF-903, page 37.
50
SENSOR_CAL_DATE
See Transducer Block Specification, part 2.
FF-903, page 37.
36
SENSOR_CAL_LOC
See Transducer Block Specification, part 2.
FF-903, page 37.
35
SENSOR_CAL_METHOD
Last calibration method. Selected from list in
Transducer Block Specification, part 2.
FF-903, page 40, section 4.5.
34
SENSOR_CAL_WHO
This is used to store the name of the
individual who last performed a calibration.
42
SENSOR_IMPEDANCE
0-10000
Ohms
This is the sensor impedance value that was
last measured.
30
SENSOR_RANGE
0-100
% O2
See Transducer Block Specification, part 2.
FF-903, page 37.
32
SENSOR_SN
See Transducer Block Specification, part 2.
FF-903, page 37.
33
Parameter Mnemonic
Valid Range
Initial
Value
Units
Description
Parameter
Number
Summary of Contents for Oxymitter 5000
Page 2: ......
Page 6: ......
Page 12: ......
Page 22: ...Oxymitter 5000 xii Instruction Manual IM 106 350 Rev 2 2 July 2008 ...
Page 42: ...Oxymitter 5000 1 20 Instruction Manual IM 106 350 Rev 2 2 July 2008 ...
Page 62: ...Oxymitter 5000 2 20 Instruction Manual IM 106 350 Rev 2 2 July 2008 ...
Page 74: ...Oxymitter 5000 4 6 Instruction Manual IM 106 350 Rev 2 2 July 2008 ...
Page 78: ...Oxymitter 5000 5 4 Instruction Manual IM 106 350 Rev 2 2 July 2008 ...
Page 94: ...Oxymitter 5000 7 6 Instruction Manual IM 106 350 Rev 2 2 July 2008 ...
Page 140: ...Oxymitter 5000 9 22 Instruction Manual IM 106 350 Rev 2 2 July 2008 ...
Page 184: ...Oxymitter 5000 B 2 Instruction Manual IM 106 350 Rev 2 2 July 2008 ...
Page 204: ...Oxymitter 5000 D 14 Instruction Manual IM 106 350 Rev 2 2 July 2008 ...
Page 222: ...Oxymitter 5000 E 18 Instruction Manual IM 106 350 Rev 2 2 July 2008 ...
Page 224: ...Instruction Manual IM 106 350 Rev 2 2 July 2008 Index 2 Oxymitter 5000 ...