PACEdge User Manual
Section 2
GFK-3178B
Nov 2020
Quick Start Guide
2
Section 2:
PACEdge Software
Note: PACEdge software comes pre-installed on Emerson Industrial PCs.
2.1
PACEdge Usage Model
PACEdge software is designed to run on the Industrial PC which is operating in a headless mode,
with the user accessing it remotely via Ethernet using the web interface.
Figure 1:Usage Model
2.2
Getting Started
1.
Connect Ethernet cable to the first Ethernet port, which is:
o
on RXi2-LP: LAN port next to the USB port
o
on RXi2-BP: ETH0 port
2.
Connect the 24V +/-25% power.
3.
Setup User PC Ethernet port IP address to be statically assigned as follows:
o
IPv4 Static IP: 192.168.3.10 (or similar in the same subnet)
o
Netmask: 255.255.255.0
4.
Power up the PACEdge unit and wait until it boots.
5.
Open the browser of choice and type in 192.168.3.100.
6.
Note: all Ethernet ports are also configured to get IP addresses assigned by the DHCP
server. This dynamically assigned IP address can also be used to access PACEdge.