2.1
General technical data
2.1.1
Ambient temperature (at rated values)
•
Permissible humidity (at rated values) Power derating (currents and torques)
•
5 - +40°C for site altitude up to 1000m amsl
•
It is vital to consult our applications department for ambient temperatures above 40°C and
encapsulated mounting of the motors.
•
95% rel. humidity, no condensation
•
1%/K in range 40°C - 50°C up to 1000m amsl for site altitude above 1000m amsl and 40°C 6%
up to 2000m amsl
•
17% up to 3000m amsl 30% up to 4000m amsl 55% up to 5000m amsl
•
No derating for site altitudes above 1000m amsl with temperature reduction of 10K / 1000m
•
Ball-bearing life
≥
20,000 operating hours
Note: Technical data for every motor type can be found in chapter "Technical Data" from (Section 7:
Technical Data).
2.1.2
Style
The basic style for the IC830M motors is style IM B5 according to EN 60034-7.
Figure 3: IC830M motors