background image

PENBERTHY 

MULTIVIEW™ TOP MOUNT MAGNETIC GAGE

INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS

Before installation these instructions must be read fully and understood

valves.emerson.com

© 2017 Emerson. All Rights Reserved.

VCIOM-03390-EN 17/05

PRODUCT WARRANTY

Emerson warrants its Penberthy products as 
designed and manufactured to be free of defects 
in material and workmanship for a period of one 
year after the date of installation or eighteen 
months after date of manufacture, whichever is 
earliest. Emerson will, at its option, replace or 
repair any products which fail during the warranty 
period due to defective material or workmanship.

Prior to submitting any claim for warranty 
service, the owner must submit proof of purchase 
to Emerson and obtain written authorization to 
return the product. Thereafter, the product shall 
be returned to Emerson, with freight prepaid.

This warranty shall not apply if the product has 
been disassembled, tampered with, repaired 
or altered outside of the Emerson factory, or 
if it has been subjected to misuse, neglect or 
accident. 
Emerson's responsibility hereunder is 
limited to repairing or replacing the product 
at its expense. Emerson shall not be liable 
for loss, damage or expenses directly or 
indirectly related to the installation or use 
of its products or from any other cause or 
for consequential damages. It is expressly 
understood that Emerson is not responsible 
for damage or injury caused to other products, 
building, property or persons, by reason of the 
installation or use of its products.

1 INTRODUCTION

The Penberthy Multiview

 top mount magnetic 

gage (TMMG) is designed for applications 
requiring visual indication but with the only access 
being a single manway in the top of the vessel.

1.1 Theory of operation 

The Multiview

 TMMG tracks the liquid level 

in a process vessel or tank by means of a float 
located in the vessel. The float is connected 
to a tube. At the opposite end of the tube is 
a magnet. The magnet is contained in the 
standpipe mounted to the vessel connection. 
As the float level changes, so does the position 
of the magnet. The level change is visually 
conveyed to the operator via the indicator 
mounted to the standpipe.
Point level control and remote continuous 
level measurement are also available. This is 
achieved by attaching electronic switches and/
or a 4-20 mA level transmitter to the exterior of 
the communicating chamber.

1.2 System description

The Penberthy Multiview™ TMMG unit consists 
of three major sections:

Standpipe chamber

The standard chamber consists of 1" Schedule 
10 pipe constructed of 304/304L STS, 
316/316L STS, Alloy 20, Monel or Hastelloy-C. 
Other chamber materials such as Inconel 625 
and Titanium may also be used.

Float

The float is constructed of 316L STS, Titanium, 
Alloy-20, Monet, Hastelloy-C or Inconel 625.

TABLE OF CONTENTS

Product warranty ................................................ 1
1 Introduction .................................................. 1
 

1.1 Theory of operation ................................ 1

 

1.2 System description ................................ 1

2 Specifications ............................................... 2
 

2.1 General ................................................... 2

 

2.2 Floats ...................................................... 2

3 Installation .................................................... 2
 

3.1 Unpacking ............................................... 2

 

3.2 Assembly ................................................ 2

 

3.3 Installation .............................................. 3

 

3.4 Indicator alignment ................................ 3

4 Start-up ........................................................ 3
5  Periodic maintenance .................................. 3
6 Troubleshooting ........................................... 4
7  Telephone assistance .................................. 4

This is Emerson's sole warranty and in lieu of 
all other warranties, expressed or implied which 
are hereby excluded, including in particular all 
warranties of merchantability or fitness for a 
particular purpose.

This document and the warranty contained 
herein may not be modified and no other 
warranty, expressed or implied, shall be made 
by or on behalf of Emerson unless made in 
writing and signed by the company's general 
manager or director of engineering.

Indicator

The indicator consists of a series of magnetically 
interlocked flags. The flags are black on one 
side and gold colored on the other. As the float 
rises the flags rotate 180°, changing from black 
to gold. Gold denotes where liquid exists, black 
where it does not. 

Summary of Contents for Penberthy Multiview

Page 1: ...r tank by means of a float located in the vessel The float is connected to a tube At the opposite end of the tube is a magnet The magnet is contained in the standpipe mounted to the vessel connection As the float level changes so does the position of the magnet The level change is visually conveyed to the operator via the indicator mounted to the standpipe Point level control and remote continuous...

Page 2: ... 316 Stainless steel Full vacuum 720 4965 Titanium Full vacuum 600 4138 Monel Full vacuum 600 4138 Alloy 20 Full vacuum 600 4138 Hastelloy C Full vacuum 750 5172 Maximum pressure rating is based on 100 F 38 C 2 2 FLOATS Float minimum specific gravity Float diameter in inches mm Minimum specific gravity 3 5 89 0 50 4 5 114 0 32 6 152 0 21 8 203 0 20 10 254 0 15 Upon receipt of the TMMG 1 The float ...

Page 3: ... these components will adversely affect the performance of your TMMG 3 Carefully insert the float float tube and float guide system if present through the vessel connection flange 4 Align the bolt pattern in the TMMG flange with the vessel flange 5 Connect the two flanges together using standard piping procedures Minimum vessel opening requirements Float diameter mm Min flange connection 3 5 89 4 ...

Page 4: ...n of non warranty units You will be contacted before we repair the unit if there will be any additional charges in excess of the minimum If you return a unit that is covered by the warranty but is not defective the minimum charge will apply 6 TROUBLESHOOTING Problem Cause Solution Loss of indication Even though there is liquid in the vessel and the float is moving freely the indicator fails to reg...