background image

Part No. F40BP74320000

Form No. BP7432

U.L. Model No.: CF905

READ AND SAVE THESE INSTRUCTIONS

Ceiling Fan Owner's Manual

CF905BS00
CF905CK00
CF905GES00

Model Numbers

PRIMA SNUGGER

Net Weight: 

18.3

Lbs.

CF905ORB00
CF905VNB00

Summary of Contents for PRIMA SNUGGER CF905BS00

Page 1: ... F40BP74320000 Form No BP7432 U L Model No CF905 READ AND SAVE THESE INSTRUCTIONS Ceiling Fan Owner s Manual CF905BS00 CF905CK00 CF905GES00 Model Numbers PRIMA SNUGGER Net Weight 18 3 Lbs CF905ORB00 CF905VNB00 ...

Page 2: ...et boxes commonly used for support of light fixtures are not acceptable for fan support and may need to be replaced Consult a qualified electrician if in doubt 5 The fan must be mounted with the fan blades at least 7 feet from the floor to prevent accidental contact with the fan blades 6 Follow the recommended instructions for the proper method of wiring your ceiling fan If you do not know enough ...

Page 3: ...qualified electrician if in doubt WARNING OUTLET BOX SCREWS 2 CEILING MOUNTING PLATE HOOK CEILING MOUNTING PLATE OUTLET BOX FAN MOTOR ASSEMBLY CEILING MOUNTING PLATE HOOK RADIAL SLOT HOLE How to Wire Your Ceiling Fan page 8 5 Connect the green grounding lead from the mounting plate and the green grounding lead from the motor assembly to the supply grounding conductor this may be a bare wire or wir...

Page 4: ...n housing trim ring over the fan housing cover 7 Position the fan housing cover over the fan motor assembly align and rotate the housing to engage the two loosened 10 24 x 3 8 pan head screw heads in the ceiling mounting plate Securely tighten both screws 8 Reinstall the previously removed 10 24 x 3 8 pan head screws to lock the housing cover onto the ceiling mounting plate 9 Push the trim ring up...

Page 5: ...e electrical shock WARNING For additional installation review full instructions on page 12 5 U L Model No CF905 SWITCH HOUSING MOUNTING PLATE HOLE 1 4 20 x 9 16 CAPTIVE FLANGE SCREW WITH LOCKWASHER 2 sets per flange BLADE FLANGE ASSEMBLY SWITCH HOUSING MOUNTING SCREW 4 SWITCH HOUSING CONNECTOR MOTOR CONNECTOR SWITCH HOUSING ASSEMBLY MOUNTING SCREWS 4 11 Attach one blade assembly to the motor using...

Page 6: ...ring outlet box and box connectors must be of type required by the local code The minimum wire would be a 3 conductor 2 wire with ground of the following size 6 Installed Wire Length Wire Size A W G Up to 50 ft 14 50 100 ft 12 Before assembly your ceiling fan refer to section on proper method of wiring your fan page 8 If you feel you do not have enough wiring knowledge or experience have your fan ...

Page 7: ...del No CF905 The fan must be hung with at least 7 of clearance from floor to blades Figure 1 WARNING To avoid possible electrical shock be sure electricity is turned off at the main fuse box before wiring NOTE If you are not sure if the outlet box is grounded contact a licensed electrician for advice as it must be grounded for safe operation WARNING To reduce the risk of fire electrical shock or p...

Page 8: ...ve been made turn leads upward and carefully push leads into the outlet box with the white and green leads on one side of the outlet box and the black and blue leads on the other side of the outlet box To avoid risk of fire or shock check to see that all connections are tight including ground and that no bare wire is visible at the wire connectors except for the ground wire Do not operate fan unti...

Page 9: ...the two remaining 10 24 x 3 8 pan head screws from the outer rim of the ceiling mounting plate Figure 6 6 Slide the fan housing trim ring over the fan housing cover Figure 7 Be sure to position the flat surface upwards towards the ceiling 7 Position the fan housing cover over the fan motor assembly Align and rotate the housing to engage the two slotted holes of the fan housing cover with the two l...

Page 10: ... sure the connector latch closes properly 13 Remove the four switch housing assembly mounting screws from the switch housing plate and retain for future use Figure 12 NOTE To install an accessory light kit remove switch housing and make light kit electrical connections to blue and white leads marked For Light in the switch housing Follow light kit instructions for wiring and installation Then rein...

Page 11: ...ng Fan REVERSE SWITCH Figure 14 1 All fans are shipped from the factory with the reversing switch positioned to circulate air downward If airflow is desired in opposite direction turn your fan off and wait for the blades to stop turning then slide the reversing switch to the opposite position and turn fan on again Figure 14 2 The fan blades will turn in the opposite direction and reverse the airfl...

Page 12: ...r provided NOTE Use wire connectors supplied to secure electrical connections 6 Attach the fan control to the wall outlet box with two 6 32 x 3 4 screws provided 7 Position the faceplate provided onto the speed control Using the two 6 32 x 1 4 screws screw the faceplate and speed control to the wall outlet box Figure 17 8 Restore power at the main fuse box or circuit breaker panel SWITCH FACEPLATE...

Page 13: ...ceiling fan additional energy and dollar savings could be realized with this simple step Turn Off When Not in the Room Ceiling fans cool people not rooms If the room is unoccupied turn off the ceiling fan to save energy Maintenance Accessories IMPORTANT CARE INSTRUCTIONS for your Ceiling Fan Periodic cleaning of your new ceiling fan is the only maintenance that is needed When cleaning use only a s...

Page 14: ...h housing 4 Check to make sure wire connectors in switch rattling housing are not rattling against each other or against the interior wall of the switch housing WARNING Make sure main power is turned OFF 5 Screws holding blades to flanges 5 Tighten screws securely are loose 6 Motor noise caused by solid state 6 Some fan motors are sensitive to signals from variable speed control Solid State variab...

Page 15: ... 764132 BK 7 Switch Housing Cover 764110 BS 764110 CK 764110 GES 764110 ORB 764110 VNB 8 Wall Control 761971 1 761971 1 761971 1 761971 1 761971 1 Parts Bag Containing 764133 764133 764133 1 764133 1 764133 1 9 Screw Washer Head Blade 10 24 x 5 16 16 10 Screw Captive Flange Head w Lkwsh 1 4 20 x 9 16 1 spare 11 Screw Switch Cup 8 32 x 5 16 1 spare 12 Screw Pan Head 10 24 x 3 8 1 spare 13 Wire Conn...

Page 16: ...orized service center call 1 800 654 3545 for the address of the nearest authorized service center You will be responsible for all insurance freight or other transportation charges to our factory or authorized service center Your Emerson Air Comfort Ceiling Fan should be properly packed to avoid damage in transit since we will not be responsible for any such damage What Is Not Covered The glass gl...