background image

GENERAL SAFETY INFORMATION

GENERAL SAFETY

 

Do not submerge motor or allow motor to be 

  exposed to water. Personal injury and/or death 

WILL result.

   

Do NOT use to pump flammable or explosive fluids such as 

gasoline, fuel oil, kerosene, etc. Do NOT use in a flammable 

and/or explosive atmosphere. Pump SHOULD only be used to 

pump clear water. Personal injury and/or death WILL result.

 

Risk of electrical shock. ALL wiring must be 

  performed by a qualified electrician.

   

Do NOT walk on wet areas until ALL power is turned off. 

Failure to follow this warning WILL result in fatal electrical 

shock.

1.  Read all instructions before operation.
2.  Disconnect power and release all pressure within 

the system before servicing any component.

3.   Drain all liquids from system before servicing.

 

Secure the discharge line before starting the 

  pump. An unsecured discharge line MAY whip. 

Personal injury and/or property damage COULD result.

4.  Periodically inspect pump and system components, checking 

for weak and/or worn hoses. Insure all connections are secure.

  

PCRP

Self-Priming  
Portable Utility Pump with Case

OPERATING INSTRUCTIONS & PARTS MANUAL

READ, UNDERSTAND AND FOLLOW ALL INSTRUCTIONS IN THIS MANUAL - DO NOT DISCARD.  

Failure to follow these instructions could result in property damage, serious injury or death.

REMINDER: Keep your dated proof of purchase for warranty purposes! Attach it to this manual or file it for safekeeping.

DESCRIPTION

This self-priming portable utility pump is designed to be used as 
a transfer pump for such applications as emptying water heaters, 
livestock tanks, etc. Pump can also be used for an intermittent 
pressure boost for applications such as washing cars, cleaning 
driveways, etc. The motor is air cooled; it is 

not

 designed to operate 

under water. 

NOTE:

 This pump is not intended for permanent installation or long, 

extended periods of continuous operation.

UNPACKING

After unpacking the utility pump, carefully inspect for any damage 
that may have occurred during transit. Check for loose, missing or 
damaged parts. If you need assistance, call our Customer Service 
Department at 1-877-9RIDGID.

SAFETY GUIDELINES

To help recognize this information, observe the following signal 
words/hazard classifications.

 

Danger indicates an imminently hazardous 

  situation which, if not avoided, WILL result in 

death or serious injury.

 

Warning indicates a potentially hazardous 

  situation which, if not avoided, COULD result in 

death or serious injury.

 

Caution indicates a potentially hazardous 

  situation which, if not avoided, MAY result in 

minor or moderate injury.

 

Notice indicates important information, that if 

  not followed, may cause damage to equipment.

 

This is the safety alert symbol. It is used to alert you to  potential bodily   

 

injury hazards. Obey all safety messages that follow this symbol to avoid  

 

possible harm.

NOTE: 

Information that requires special attention.

Specifications

Motor

Single Phase - 115V, 60 Hz, 8,000 RPM

Horsepower

1/2 HP

Motor

Series Wound (brush type) AC/DC Operation

Inlet/Outlet Openings

3/4 inch NPT

Impeller

Thermoplastic

Pump Housing

Cast iron

Motor Housing

Cast iron

Motor Shaft

Cold rolled steel

Shaft and Volute 
Seal

Buna-N

Motor Bearings

Permanently lubricated 
Rolling element bearings

Maximum Fluid 
Temperature

120°F

3213 

05

 -005 A 8/17

© 2017, Ridge Tool Company.

Summary of Contents for RIDGID PCRP

Page 1: ...r heaters livestock tanks etc Pump can also be used for an intermittent pressure boost for applications such as washing cars cleaning driveways etc The motor is air cooled it is not designed to operate under water NOTE This pump is not intended for permanent installation or long extended periods of continuous operation UNPACKING After unpacking the utility pump carefully inspect for any damage tha...

Page 2: ...th 25 ft 50 ft 100 ft 150 ft Risk of fatal electrical shock NEVER cut off the round grounding prong Cutting the cord or plug WILL void the warranty and make the pump inoperable GENERAL SAFETY INFORMATION CONTINUED Pump motor is equipped with an automatic resetting thermal protector and MAY restart unexpectedly Protector tripping is an indication of motor overheating because of operating pump at lo...

Page 3: ... GFCI protected electrical outlet The pump will prime in a few minutes depending on suction line length Use of foot valve on suction line is recommended 4 In the case of pressure boosting turn water on before starting pump This force primes the pump Then plug power cord into GFCI protected electrical outlet 5 Unplug cord to turn unit off MAINTENANCE Let pump cool for at least 20 minutes before att...

Page 4: ...al seats against the back head and making sure the black carbon side of the seal is facing away from the back head towards the impeller 10 Push the ceramic seal into the impeller pocket making sure the white ceramic surface faces away from the back of the impeller 11 Holding the rotor with one hand thread the new impeller onto the rotor shaft making sure it is tight on the shaft and the white face...

Page 5: ...4 Lower pump 5 Hose kinked or looped 5 Straighten hose 6 Fittings not tight 6 Tighten fittings 7 Suction hose out of water 7 Submerge suction hose end 8 Clogged inlet 8 Clean inlet Flow rate is too low 1 Piping or hose is fouled or damaged 1 Clean or replace 2 Low line voltage 2 Contact an electrician Seal leaks 1 Worn seal 1 Replace seal 2 Backhead damaged or cracked 2 Replace backhead 3 Pump hea...

Page 6: ...Model number Serial number if any Part description and number as shown in parts list Address parts correspondence to RIDGID PUMPS 101 Production Drive Harrison OH 45030 U S A 6 REPLACEMENT PARTS LIST Ref No Description Part Number Qty 1 Brush kit 62015 WYN1 1 2 Impeller and seal kit 56671 WYN1 1 Note Replacement parts are available in kit form only ...

Page 7: ...PCRP 7 NOTES ...

Page 8: ...t alteration improper installation or maintenance modification repair by other than a service center authorized to repair RIDGID brand water pumps or failure to operate in accordance with RIDGID water pump written instructions WAYNE WATER SYSTEMS MAKES NO OTHER EXPRESS WARRANTIES REPRESENTATIONS OR PROMISES AS TO THE QUALITY OR PERFORMANCE OF ITS WATER PUMPS OTHER THAN THOSE SPECIFICALLY STATED IN...

Page 9: ...o bombas de desagüe para vaciar calentadores de agua tanques para animales etc Igualmente las bombas se pueden usar de modo intermitente para lavar coches limpiar entradas de garajes etc El motor se enfría con aire y no está diseñado para operar bajo agua NOTA Este bomba no está diseñada para una instalación permanente o para períodos de trabajo continuo largos y extendidos PARA DESEMPACAR Después...

Page 10: ... CONTINUACION Asegure la línea de descarga antes de dar arranque a la bomba Si no la asegura ES POSIBLE que se sacuda bruscamente y PODRÍAN causarse lesiones personales y o daños a la propiedad 4 Periódicamente inspeccione la bomba y los componentes chequée si las mangueras están debilitadas o desgastadas Cerciórese de que todas las conecciones estén bien apretadas El motor de la bomba está equipa...

Page 11: ...e las escobillas y quitarle los residuos de carbón Las escobillas no están cubiertas en la garantía Para ordenar escobillas de repuesto comuníquese con el distribuidor de bombas RIDGID más cercano a su domicilio En EUA llame al 1 877 9RIDGID para ordenarlas 1 Desconecte el cordón eléctrico del tomacorrientes 2 Use un desarmador para quitarle las tapas a las escobillas 3 Saque el ensamblaje de las ...

Page 12: ...zal trasero asegurándose de que la brida del sello se asiente contra el cabezal trasero y asegurándose de que el lado de carbón negro del sello esté orientado lejos del cabezal trasero y hacia el impulsor 10 Empuje el sello de cerámica hacia dentro de la cavidad del impulsor asegurándose de que la superficie de cerámica blanca esté orientada hacia la parte trasera del impulsor 11 Sosteniendo el ro...

Page 13: ...enrollada 5 Enderece la manguera 6 Las conexiones están flojas 6 Apriete las conexiones 7 La manguera de succión no tiene agua 7 Sumerja el extremo de la manguera de succión 8 El orificio de entrada está obstruído 8 Limpie el orificio de la entrada El flujo es muy bajo 1 Las tuberías o mangueras están obstruídas o dañadas 1 Límpielas o reemplácelas 2 El voltaje es muy bajo 2 Póngase en contacto co...

Page 14: ...ás Cercano a Su Domicilio Sirvase darnos la siguiente información Dirija toda la correspondencia a Número del modelo RIDGID PUMPS Código impreso 101 Production Drive Descripción y número del repuesto según la lista de repuestos Harrison OH 45030 U S A LISTA DE PARTES DE REPARACIÓN No de Ref Descripción Número de Parte Ctd 1 Juego de escobillas 62015 WYN1 1 2 Juego de propela y sellos 56671 WYN1 1 ...

Page 15: ...PCRP Sp 15 NOTAS ...

Page 16: ...eración instalación o mantenimiento inadecuados modificación reparación por una persona que no esté autorizada por el centro de servicio para reparar bombas de agua de la marca RIDGID o la incapacidad de funcionar de acuerdo con las instrucciones escritas de la bomba de agua RIDGID WAYNE WATER SYSTEMS NO PROPORCIONA NINGUNA GARANTÍA REPRESENTACIÓN NI PROMESA EXPRESA SOBRE LA CALIDAD O EL FUNCIONAM...

Reviews: