62
Reference Manual
00809-0400-4101, Rev BA
Troubleshooting
January 2018
Troubleshooting
1. Remove the housing cover from the field terminal side.
2. Loosen the two small screws located on the assembly in the 9 and 5 o’clock positions relative to the
top of the transmitter.
3. Pull the entire terminal block out to remove it.
6.4.3
Removing the LOI or LCD display
Rosemount 2051G with M4 or M5 option codes have and LOI or LCD display. The transmitter LOI/LCD
display are located in the compartment opposite the terminal side. To remove and/or replace the
LOI/LCD display, perform the following procedures:
1. Remove the housing cover opposite the field terminal side.
2. Loosen the two captive screws that are visible (See
for screw locations). The
two screws anchor the LOI/LCD display to the electronics board and the electronics board to the
housing.
3. After the screws are loosened, pull the LOI/LCD display off of the electronics board and out of the
housing. Make sure to pull directly backwards so to not bend or damage the connection pins on the
electronics board.
Note
Ensure not to attempt to pull out the electronics board from the housing as this could permanently
damage the transmitter.
6.5
Reassembly procedures
6.5.1
Installing LOI/LCD display
1. While aligning the captive screws with the respective holes on the electronics board, connect the
LCD/LOI display to the electronics board by pressing down firmly.
2. Make sure the connecting pins on the back of the LCD fully connect to the front of the electronics
board.
3. Fully tighten down the captive screws
4. Replace the housing cover. The transmitter must be fully engaged to meet Explosion-Proof
requirements.
6.6
Service support
Within the United States, call the Emerson
™
Instrument and Valve Response Center using the
1-800-654-RSMT (7768) toll-free number. This center, available 24 hours a day, will assist you with any
needed information or materials.
The center will ask for product model and serial numbers, and will provide a Return Material
Authorization (RMA) number. The center will also ask for the process material to which the product was
last exposed.
for complete warning.
Summary of Contents for Rosemount 2051G
Page 2: ......
Page 10: ...2 Reference Manual 00809 0400 4101 Rev BA Introduction January 2018 Introduction ...
Page 34: ...26 Reference Manual 00809 0300 4410 Rev BA Configuration January 2018 Configuration ...
Page 72: ...64 Reference Manual 00809 0400 4101 Rev BA Troubleshooting January 2018 Troubleshooting ...
Page 89: ......