142
Specifications and Reference Data
Specifications and Reference Data
October 2017
Reference Manual
00809-0100-2240, Rev DA
A.3 Configuration specifications
A.3.1 Configuration tool
TankMaster WinSetup is the recommended tool for easy
configuration of Rosemount 2240S. The Tankbus
autoconfiguration feature, handled by the Rosemount 2410 Tank
Hub, supports Rosemount 2240S.
A.3.2 Configuration parameters (examples)
Temperature
Number of temperature sensor elements
Temperature element type (spot or average)
Temperature element position in tank
Water Level Sensor
Level offset (difference between tank zero level and water zero
level)
Probe length (autoconfigured by Rosemount 765)
A.3.3 Output variables and units
Spot and average temperature: °C (Celsius), and °F (Fahrenheit)
Free water level (FWL): meter, centimeter, millimeter, feet, or inch
A.4 F
OUNDATION
fieldbus characteristics
A.4.1 Polarity sensitive
No
A.4.2 Quiescent current draw
30 mA
A.4.3 Lift-off minimum voltage
9.0 VDC
A.4.4 Device capacitance / inductance
“Product Certifications” on page 149
A.4.5 Class (Basic or Link Master)
Link Master (LAS)
A.4.6 Number of available VCRs
Maximum 20, including one fixed
A.4.7 Links
Maximum 40
A.4.8 Minimum slot time/maximum response
delay/minimum intermessage delay
8 / 5 / 8
A.4.9 Blocks and Execution time
1 Resource block,
3 Transducer blocks (Temperature, Register, AVG_Temp),
2
Multiple Analog Input (MAI) blocks: 15 ms,
6 Analog Input (AI) blocks: 10 ms,
1 Analog Output (AO) block: 10 ms,
1 Signal Characterizer (SGCR) blocks: 10 ms,
1 Proportional/Integral/Derivate (PID) block: 15 ms,
1 Integrator (INT) block: 10 ms
1 Arithmetic (ARTH) block: 10 ms,
2 Input Selector (ISEL) block: 10 ms
1 Control Selector (CS) block: 10 ms,
1 Output Splitter (OS) block: 10 ms
For more information, see the Foundation™ fieldbus Blocks
manual (document no. 00809-0100-4783)
A.4.10 Instantiation
Yes
A.4.11 Conforming F
OUNDATION
fieldbus
ITK 6
A.4.12 Field Diagnostics support
Yes
A.4.13 Action support wizards
Restart/stop measurement, write protect device, factory reset -
measurement configuration, reset statistics, start/stop device
simulation
A.4.14 Advanced diagnostics
Failures/Out of specification/Maintenance required alerts:
Software, memory/database, electronics, internal
communication, simulation, auxiliary device, auxiliary device
measurement, ambient temperature, average temperature
measurement, temperature measurement, configuration
Summary of Contents for Rosemount 2240S
Page 2: ......
Page 10: ...viii Reference Manual 00809 0100 2240 Rev DA Title Page October 2017 Title Page ...
Page 16: ...6 Reference Manual 00809 0100 2240 Rev DA Introduction October 2017 Introduction ...
Page 28: ...18 Reference Manual 00809 0100 2240 Rev DA Overview October 2017 Overview ...
Page 192: ...182 Reference Manual 00809 0100 2240 Rev DA Index October 2017 Index ...
Page 193: ......