27
Reference Manual
00809-0100-4825, Rev CB
Section 3: Configuration
March 2014
Configuration
3.4.2
HART device dashboard menu tree
Home
1 Overview
2 Configure
3 Service tools
Overview
1 Device status
2 Primary variable is
3 Sensor temperature
4 Analog output value
5 Upper range Value
6 Lower range value
7 Device information
Device Information
1 Identification
2 Revision information
3 Alarm type and security
Revision Information
1 HART universal
2 Device
3 Hardware
4 Software
5 Device driver
Device Status
1 Active alerts
Active Alerts
1 Good (only if no alerts)
2 Failed (fix now)
3 Maintenance
Good
1 Refresh alerts
2 No active alert
Failed
1 Refresh alerts
2 Memory failure
3 Sensor error/open
4 Sensor short
5 Terminal temperature failure
6 Electronics failure
7 Invalid configuration
8 Calibration failure
9 Sensor degraded
10 Sensor out of range
11 Terminal temp out of range
Maintenance
1 Refresh alerts
2 Invalid configuration
3 Calibration error
4 Sensor degraded
5 Sensor out of range
6 Terminal temp out of range
Configure
1 Guided setup
2 Manual setup
Guided Setup
1 Configure sensor
2 Calibrate sensor
3 Configure device
Sensor
1 Sensor value
2 Type
3 Connection
4 Units
5 Two Wire offset
6 Damping
7 Serial number
8 Upper sensor limit
9 Lower sensor limit
Manual Setup
1 Sensor
2 Analog output
3 Device
4 HART
Analog Output
1 Sensor value
2 Analog output
3 Percent range
4 Configuration
5 Alarm/Sat levels
Device
1 Identification
2 Device temp units
3 Open sensor hold off
4 Security enable/disable
5 Noise rejection
HART
1 Polling address
2 Burst mode
3 Burst option
Noise Rejection
1 AC oower filter
2 Transient filter threshold
Alarm/Sat Levels
1 High alarm level
2 Low alarm level
3 High sat level
4 Low sat level
5 Alarm direction
Configuration
1 Primary variable is
2 Upper range value
3 Lower range value
4 Minimum span
Identification
1 Tag
2 Date
3 Message
4 Descriptor
5 Final assembly no.
Service Tools
1 Alerts
2 Variables
3 Trends
4 Maintenance
5 Simulate
Alerts
1 Refresh alerts
2 No Active alerts
3 Memory failure
4 Sensor error/open
5 Sensor short
6 Terminal temp failure
7 Electronics failure
8 Invalid configuration
9 Calibration error
10 Sensor degraded
11 Sensor out of range
12 Terminal temp out of range
Variables
1 Variable summary
2 Sensor temperature (gauge)
3 Terminal temperature (guage)
4 Analog output (guage)
Trends
1 Sensor value (trend)
2 Terminal temperature (trend)
Maintenance
1 Sensor calibration
2 Analog trim
3 Scaled trim
4 Master reset
Simulate
1 Loop test
Sensor Calibration
1 Calibrate sensor
2 Restore factory cal
3 Calibration mode
4 Lower cal point
5 Upper cal point
Identification
1 Tag
2 Model
3 Device ID
4 Serial number
5 Final assembly number
6 Date
7 Descriptor
8 Message
Alarm type and Security
1 Alarm direction
2 Security status
3 Saturation level
4 Alarm level
Saturation Level
1 High sat level
2 Low sat level
Alarm Level
1 High alarm level
2 Low alarm level