Quick Start Guide
3
June 2016
Figure 1. Rosemount 485 Annubar Flanged Flo-Tap Assembly Exploded View
Note
Use an appropriate pipe sealing compound rated for the service temperature on all
threaded connections.
A. Transmitter
I. Isolation valve
B. 2
⫻
O-rings
J. Cage nipple
C. Temperature sensor connection housing
K. Support plate
D. Direct mount transmitter connection with valves L. Packing gland
E. Head plate
M. Packing
F. Drive rods
N. Follower
G. Mounting flange assembly
O. Compression plate
H. Gasket
P. Coplanar flange with drain vents
P
A
B
C
D
E
F
O
N
M
L
K
J
I
H
G