Rosemount LinkPro Operating Instructions
November 2017
Reference Manual
00809-0100-4570, Rev DA
Rosemount LinkPro Operating Instructions
173
Selecting connection cable
The Rosemount LinkPro is connected to a power supply with a standard cable that meets local regulatory
standards. RS-485 rated cable with screening should be used to connect the sensors. Screening is
necessary to ensure interference-free operation with other devices. The communication cable should be
twisted pair and shielded, rated for a RS-485 communication standard, and have 120 Ohm impedance.
Cable screening and grounding
The communication cable shield must be grounded. Connect the shield in the Rosemount 5708
grounding point on one end and to a dedicated grounding on the other end. This can be, for example,
the ‘-’ port of the power supply.
D.5.2
Wiring plan
This section provides details of how to connect the wires.
Power supply
Detailed information on the power supply can be found in the
“Technical specifications” on page 168
.
To connect to a power supply:
1. Loosen the four Rosemount LinkPro housing screws using a flat screwdriver.
2. Remove the housing cover.
3. Insert the Rosemount 5708 cable through the left gland of the Rosemount LinkPro.
4. Loosen the terminals with a small, flat screwdriver.
5. Connect the power supply wires to sockets “1” and “2” in accordance with
. Note the
polarity.
6. Tighten the screws of the terminal.
7. Tighten the compression nut of the cable entry. The seal ring must wrap the cable completely.
8. Connect sockets “3” and “4” with a separate cable to the Rosemount LinkPro.
9. Screw on the Rosemount LinkPro housing cover.
10.If the cable is screened, refer to
“Cable screening and grounding” on page 173
.
Summary of Contents for Rosemount 5708
Page 1: ...Reference Manual 00809 0100 4570 Rev DA November 2017 Rosemount 5708 3D Solids Scanner ...
Page 2: ...ii Section Title November 2017 Reference Manual 00809 0100 4570 Rev DA ...
Page 8: ...vi Reference Manual 00809 0100 4570 Rev DA Contents November 2017 Contents ...
Page 12: ...2 Reference Manual 00809 0100 4570 Rev DA Introduction November 2017 Introduction ...
Page 202: ...ii Reference Manual 00809 0100 4570 Rev DA Index November 2017 Index ...
Page 203: ...iii Reference Manual 00809 0100 4570 Rev DA November 2017 ...