Mechanical Installation
November 2017
Mechanical Installation
Figure 3-3. Standpipe Mounting
Note
Any obstruction as well as rails, frames or support beams should never interfere with the acoustic beam
transmitted and received, as shown in
.
Figure 3-4. Avoid Interference with the Acoustic Beam
Inflowing material
Do not mount the Rosemount 5708 in or above the filling stream, or close to the stream, or in the filling
stream. The Rosemount 5708 should be located with a clear line of sight to the top of the material at
high levels, where it will not be affected by the filling stream or the noise it creates.
0.4-in. (10 mm)