time before it jumps to the new echo. In the mean time the gauge decides whether the
new echo can be considered a valid echo.
The Jump Filter does not use the Distance Filter Factor and can be used at the same time as
the Least Square or the Adaptive Filter functions.
Least Square Filter
The Least Square filter gives increased accuracy for slow filling or emptying of a tank. The
level value follows the surface with high accuracy and without delay as the level changes.
The Least Square filter can not be used at the same time as the Adaptive Filter.
Adaptive Filter
The Adaptive Filter automatically adapts to the movement of the surface level. It tracks
product level fluctuations and continuously adjusts the filter grade accordingly. The filter
can preferably be used in tanks in which fast tracking of level changes are important and
turbulence occasionally cause unstable level readings.
Reference Manual
Configuration
00809-0100-5901
September 2019
Rosemount 5900C Radar Level Gauge
137
Summary of Contents for Rosemount 5900C
Page 1: ...Reference Manual 00809 0100 5901 Rev DA September 2019 Rosemount 5900C Radar Level Gauge ...
Page 6: ...Contents Reference Manual September 2019 00809 0100 5901 vi Reference Manual ...
Page 12: ...Introduction Reference Manual September 2019 00809 0100 5901 12 Reference Manual ...
Page 116: ...Installation Reference Manual September 2019 00809 0100 5901 116 Reference Manual ...
Page 204: ...Configuration Reference Manual September 2019 00809 0100 5901 204 Reference Manual ...
Page 208: ...Operation Reference Manual September 2019 00809 0100 5901 208 Reference Manual ...
Page 290: ...Product Certifications Reference Manual September 2019 00809 0100 5901 290 Reference Manual ...