6.2.2
Backing up the level gauge configuration
Input and holding registers for the Rosemount 5900C Radar Level Gauge can be stored on
disk. This can be useful for backup purposes and troubleshooting. You can save a
predefined set of holding registers to make a backup copy of the current gauge
configuration. The backup file can be used to restore the level gauge configuration.
Backing up a device configuration using TankMaster
™
Using Rosemount TankMaster WinSetup to save the current device configuration to file:
Procedure
1. Start the Rosemount TankMaster WinSetup program.
2. In the
TankMaster WinSetup
workspace window, right-click the device icon.
3. Choose the
Save Database to File
option.
This option is also available from the
Service/Devices
menu.
4. Choose the
Holding Registers
and
Predefined Registers
options (the User-Defined
option should only be used for advanced service).
5. Click the
Browse
button, select a folder and type a name for the backup file.
6. Click the
Save
button to start saving the database registers.
Service and troubleshooting
Reference Manual
September 2019
00809-0100-5901
212
Reference Manual
Summary of Contents for Rosemount 5900C
Page 1: ...Reference Manual 00809 0100 5901 Rev DA September 2019 Rosemount 5900C Radar Level Gauge ...
Page 6: ...Contents Reference Manual September 2019 00809 0100 5901 vi Reference Manual ...
Page 12: ...Introduction Reference Manual September 2019 00809 0100 5901 12 Reference Manual ...
Page 116: ...Installation Reference Manual September 2019 00809 0100 5901 116 Reference Manual ...
Page 204: ...Configuration Reference Manual September 2019 00809 0100 5901 204 Reference Manual ...
Page 208: ...Operation Reference Manual September 2019 00809 0100 5901 208 Reference Manual ...
Page 290: ...Product Certifications Reference Manual September 2019 00809 0100 5901 290 Reference Manual ...