Table 6-1: Troubleshooting Chart for the Rosemount 5900C
(continued)
Symptom
Possible cause
Action
Incorrect configuration of
the Rosemount 2410 Tank
Hub’s tank database
•
Check the Rosemount 2410 tank database; ensure that
the level gauge is available and mapped to the right
tank
•
In Rosemount TankMaster WinSetup open the
Rosemount 2410 Tank Hub /Tank Database
window and
check that the Level Modbus address is equal to the
2410 Level Modbus address in the Rosemount 2460
System Hub’s tank database
•
See the Rosemount Tank Gauging
for more information on how to
configure the 2410 tank database
Software or hardware failure
•
Check diagnostics information, see
diagnostic registers using TankMaster
•
Check Device Status input register, see
•
Contact Emerson Automation Solutions /Rosemount
Tank Gauging service department
Incorrect level
measurement
Incorrect configuration
•
Check configuration of tank geometry and antenna
parameters: - Tank Reference Height (R) - Gauge
Reference Distance (G) - Calibration distance - Antenna
type - Antenna size (Still pipe Array) See the
Rosemount Tank Gauging
for more information on how to use
Rosemount TankMaster WinSetup for configuration of
tank geometry and antenna parameters.
•
Verify that the mechanical installation of the
Rosemount 5900C fulfills installation requirements.
Check for example: - nozzle height and diameter -
obstacles in the vicinity of the nozzle - distance to tank
wall - inclination - total slot/hole area in still pipe See
chapter
•
Check configuration of Environment parameters such
as Foam, Turbulent Surface etc. and other advanced
configuration options. WinSetup: Rosemount 5900C
Properties/Environment, Rosemount 5900C
Properties/Advanced Configuration.
•
Check status and diagnostics information, see
and configure diagnostic registers using TankMaster
.
Service and troubleshooting
Reference Manual
September 2019
00809-0100-5901
228
Reference Manual
Summary of Contents for Rosemount 5900C
Page 1: ...Reference Manual 00809 0100 5901 Rev DA September 2019 Rosemount 5900C Radar Level Gauge ...
Page 6: ...Contents Reference Manual September 2019 00809 0100 5901 vi Reference Manual ...
Page 12: ...Introduction Reference Manual September 2019 00809 0100 5901 12 Reference Manual ...
Page 116: ...Installation Reference Manual September 2019 00809 0100 5901 116 Reference Manual ...
Page 204: ...Configuration Reference Manual September 2019 00809 0100 5901 204 Reference Manual ...
Page 208: ...Operation Reference Manual September 2019 00809 0100 5901 208 Reference Manual ...
Page 290: ...Product Certifications Reference Manual September 2019 00809 0100 5901 290 Reference Manual ...