Procedure
1. Put the O-ring on the flange and insert the Flange Ball into the hole. Make sure that
the guide pin on the side of the Flange Ball fits into the recess on the flange.
$
%
A. Flange Ball
B. Nut
2. Tighten the nut so that the Flange Ball fits tightly to the flange (torque 50 Nm).
Mounting the welded Flange Ball
Follow this instruction when installing the welded Flange Ball on a flange.
Prerequisites
For horizontal mounting according to requirements in chapter
, make sure that the diameter of the hole is 116 ± 2 mm.
Figure 3-21: Flange Requirements
$
%
A. 116±2 mm
B. 6-38 mm
Installation
Reference Manual
September 2019
00809-0100-5901
50
Reference Manual
Summary of Contents for Rosemount 5900C
Page 1: ...Reference Manual 00809 0100 5901 Rev DA September 2019 Rosemount 5900C Radar Level Gauge ...
Page 6: ...Contents Reference Manual September 2019 00809 0100 5901 vi Reference Manual ...
Page 12: ...Introduction Reference Manual September 2019 00809 0100 5901 12 Reference Manual ...
Page 116: ...Installation Reference Manual September 2019 00809 0100 5901 116 Reference Manual ...
Page 204: ...Configuration Reference Manual September 2019 00809 0100 5901 204 Reference Manual ...
Page 208: ...Operation Reference Manual September 2019 00809 0100 5901 208 Reference Manual ...
Page 290: ...Product Certifications Reference Manual September 2019 00809 0100 5901 290 Reference Manual ...