A
Specifications and reference data
A.1
Specifications
A.1.1
Functional specifications
Discrete output, models 928XSS01, 928XUT01
Maximum rating: 28 Vdc, 100 mA
On resistance: typical 1 Ohm
Wireless output
IEC 62591 (
Wireless
HART
®
) Compliant, 2.4 GHz
Antenna radio frequency power output
External (WK option) antenna: Maximum of 10 mW (10 dBm) EIRP
Extended range, external (WM option) antenna: Maximum of 18 mW (12.5 dBm) EIRP
High gain, remote (WN option) antenna: Maximum of 40 mW (16 dBm) EIRP
Remote, extended (WJ option) antenna: Maximum of 18 mW (12.5 dBm) EIRP
Local display
The integral LCD display can display alert state and diagnostic information. Configurable
to display updates at each wireless update.
Humidity limits
Maximum inputs for the Rosemount 928 (ordinary and IS
environments)
28 Volts
95 milliamps
650 milliwatts
Wireless update rate
User selectable, 1 second to 60 minutes
Reference Manual
Specifications and reference data
00809-0100-4928
September 2019
Rosemount 928
179