Special Conditions for Safe Use (X):
1. For use only with the Emerson Model 701PBKKF, the Computations Systems, Inc.
MHM-89004, or the Perpetuum Ltd. IPM71008/IPM74001.
Pour utilization uniquement avec Emerson Model 701PBKKF, Computation Systems, Inc
MHM-89004, ou Perpetuum Ltd. IPM71008/IPM74001.
2. The surface resistivity of the antenna is greater than 1 GΩ. To avoid electrostatic
discharge buildup, it must not be rubbed or cleaned with solvents or a dry cloth.
La résistivité de surface du bo
ȋ
tier est supérieure à un gigaohm. Pour éviter
l’accumulation de charge électrostatique, ne pas frotter ou nettoyer avec des produits
solvants ou un chiffon sec.
3. Substitution of components may impair Intrinsic Safety.
La substitution de composants peut compromettre la sécurité intrinsèque.
B.8
Europe
I1 ATEX Intrinsically Safe (IS)
Certificate
Sira17ATEX2371X
Standards
EN 60079-0:2012 + A11:2013, EN 60079-11:2012
Markings
II1 G
Ex ia IIC T4 Ga;
T4 (-40 °C ≤ Ta ≤ +50 °C)
Type IP66
Refer to
Special Conditions for Safe Use (X):
1. Under certain extreme circumstances, the non-metallic parts incorporated in the
enclosure of this equipment may generate an ignition capable of electrostatic
charge. Therefore, the equipment shall not be installed in a location where the
external conditions are conducive to the build-up of electrostatic charge on such
surfaces. In addition, the equipment shall only be cleaned with a damp cloth.
2. The transmitter may contain more than 10 percent aluminum and is considered a
potential risk ignition by impact or friction. Care must be taken into account during
installation and use to prevent impact or friction.
3. The equipment shall be powered by Emerson 701PBKKF. An alternative power
source shall be the CSI MHM-89004, as these devices have output parameters that
are equal or less onerous than the parameters of the 701PBKKF.
4. Only the 375, 475, or AMS Trex Communicators may be used with the Rosemount
928.
Reference Manual
Product certifications
00809-0100-4928
September 2019
Rosemount 928
189
Summary of Contents for Rosemount 928
Page 1: ...Reference Manual 00809 0100 4928 Rev AE September 2019 Rosemount 928 Wireless Gas Monitor ...
Page 4: ...4 ...
Page 8: ...Contents Reference Manual September 2019 00809 0100 4928 viii Emerson com Rosemount ...
Page 106: ...Configuration Reference Manual September 2019 00809 0100 4928 106 Emerson com Rosemount ...
Page 178: ...Troubleshooting Reference Manual September 2019 00809 0100 4928 178 Emerson com Rosemount ...