background image

Figure 2-12: Install plugs

13. Reinstall the end caps on each end of the upper electronics enclosure.

a) Reapply power to the unit.

Figure 2-13: Install end caps

Installation of the Option Board

Installation Procedure

February 2022

 00809-0100-3105

22

Emerson.com/Rosemount

Summary of Contents for Rosemount Ultrasonic 100 Series

Page 1: ...Installation Procedure 00809 0100 3105 Rev AA February 2022 Rosemount Ultrasonic Series 100 Option Board Field ...

Page 2: ...equipment These procedures ensure legal compliance with government transportation agencies and help provide a safe working environment for Emerson employees Emerson will not accept your returned equipment if you fail to follow Emerson procedures Return procedures and forms are available on our web support site at Emerson com or by phoning the Emerson Customer Service department Emerson Flow custom...

Page 3: ...start 7 Part II Install Chapter 2 Installation of the Option Board 13 2 1 Instructions before opening the unit 13 2 2 Instructions to install the Option Board 13 Appendix A Engineering Drawings 23 Installation Procedure Contents 00809 0100 3105 February 2022 Rosemount Ultrasonic Series 100 Option Board Field 3 ...

Page 4: ...Contents Installation Procedure February 2022 00809 0100 3105 4 Emerson com Rosemount ...

Page 5: ...Part I Plan Installation Procedure Plan 00809 0100 3105 February 2022 Rosemount Ultrasonic Series 100 Option Board Field 5 ...

Page 6: ...Plan Installation Procedure February 2022 00809 0100 3105 6 Emerson com Rosemount ...

Page 7: ...before taking the Ultrasonic meter out of service 1 2 1 Required parts Series 100 Option Board Field Installation Kit P N 2 9 3400 844 Series 100 Option Board Field Installation Kit w Keys P N 2 9 3400 845 Series 100 Plus HART Option Board Field Installation Kit P N 2 9 3400 855 Series 100 Plus HART Option Board Field Installation Kit w Keys P N 2 9 3400 856 The kits contain the following componen...

Page 8: ...dard Edition Installation CD 1 Contains upgrade to latest Deluxe Edition of Daniel CUI if Deluxe Edition already installed on computer 1 Contains upgrade to latest Ultrasonic firmware upgrade that supports Series 100 Option Board 4 Feature keys will be supplied by a Customer Service Representative for kits including keys for Ethernet Archive Logs AGA 10 and GC Master 1 2 2 Required tools A 1 8 fla...

Page 9: ... Ground strap Installation Procedure Introduction 00809 0100 3105 February 2022 Rosemount Ultrasonic Series 100 Option Board Field 9 ...

Page 10: ...Introduction Installation Procedure February 2022 00809 0100 3105 10 Emerson com Rosemount ...

Page 11: ...Part II Install Installation Procedure Install 00809 0100 3105 February 2022 Rosemount Ultrasonic Series 100 Option Board Field 11 ...

Page 12: ...Install Installation Procedure February 2022 00809 0100 3105 12 Emerson com Rosemount ...

Page 13: ...tronics can result in damage to the equipment 2 2 Instructions to install the Option Board Procedure 1 Before disconnecting unit power to install the option board connect to the meter with Daniel CUI and make sure the meter has the latest version of firmware installed for meter If you install an option board in a meter with firmware that does not support the board the meter will not be able to rec...

Page 14: ...ter version of firmware is included The firmware for your meter can be found under one of the following directories on the CD Ultrasonic Gas Rosemount Mark III Firmware Ultrasonic Liquid Rosemount 3800 Firmware Use the Program Download utility under the Tools pull down menu in Daniel CUI to upgrade the firmware in the meter if necessary Clicking F1 with the Program Download utility open will displ...

Page 15: ...e screws Disconnect the cable and remove the CPU board from the enclosure Figure 2 3 Remove CPU board 5 Use a Phillips head screwdriver to remove the washers and screws from the three standoffs attached to the Option board Installation Procedure Installation of the Option Board 00809 0100 3105 February 2022 Rosemount Ultrasonic Series 100 Option Board Field 15 ...

Page 16: ...Figure 2 4 Prepare Option board Installation of the Option Board Installation Procedure February 2022 00809 0100 3105 16 Emerson com Rosemount ...

Page 17: ...Figure 2 5 Option Board Connectors Switches LEDs Installation Procedure Installation of the Option Board 00809 0100 3105 February 2022 Rosemount Ultrasonic Series 100 Option Board Field 17 ...

Page 18: ...ided as a reference 7 Install the Option board on the CPU board making sure that the connector on the bottom of the Option board mates to the connector on top of the CPU board Figure 2 7 Mount Option board 8 Secure the Option board to the CPU board with the three Kep screws Installation of the Option Board Installation Procedure February 2022 00809 0100 3105 18 Emerson com Rosemount ...

Page 19: ... with the newer revision a Use a hex driver to remove the nut that attaches the Wiring Diagram Card Remove the old card and install the new card provided with the Option Board Kit Secure the card in place with the hex nut Installation Procedure Installation of the Option Board 00809 0100 3105 February 2022 Rosemount Ultrasonic Series 100 Option Board Field 19 ...

Page 20: ...ining screws Figure 2 10 Attach acquisition cable to CPU board 11 Slide the CPU board back onto the card guides and seat it in the Field Connection board Push the locking mechanism on both card guides to the Locked position as Installation of the Option Board Installation Procedure February 2022 00809 0100 3105 20 Emerson com Rosemount ...

Page 21: ...the Field Connection board as shown The Series 100 Option board will have plugs fully populating connectors J11 and J12 The Series 100 Plus HART Option board will have plugs fully populating connector J10 J11 and J12 a Install wiring and conduit for the Option board I O Installation Procedure Installation of the Option Board 00809 0100 3105 February 2022 Rosemount Ultrasonic Series 100 Option Boar...

Page 22: ...nstall the end caps on each end of the upper electronics enclosure a Reapply power to the unit Figure 2 13 Install end caps Installation of the Option Board Installation Procedure February 2022 00809 0100 3105 22 Emerson com Rosemount ...

Page 23: ...E 21056 Mark III Ultrasonic System Wiring Ultrasonic Flowmeter Model 3400 3410 and 3420 Sheets 1 3 Installation Procedure Engineering Drawings 00809 0100 3105 February 2022 Rosemount Ultrasonic Series 100 Option Board Field 23 ...

Page 24: ...Mark III Ultrasonic System Wiring Ultrasonic Flowmeter Model 3400 3410 and 3420 DE 21056 Engineering Drawings Installation Procedure February 2022 00809 0100 3105 24 Emerson com Rosemount ...

Page 25: ...er Model 3400 3410 and 3420 DE 21056 Mark III Ultrasonic System Wiring Ultrasonic Flowmeter Model 3400 3410 and 3420 DE 21056 Installation Procedure Engineering Drawings 00809 0100 3105 February 2022 Rosemount Ultrasonic Series 100 Option Board Field 25 ...

Page 26: ... All rights reserved Emerson Terms and Conditions of Sale are available upon request The Emerson logo is a trademark and service mark of Emerson Electric Co Rosemount is a mark of one of the Emerson family of companies All other marks are the property of their respective owners ...