RXi2-UP IPC Hardware Reference Manual
Section 8
GFK-3047D
Oct 2021
Specifications
51
8.2
Environmental Specifications
8.2.1
Ambient Temperatures and Humidity
Ambient temperatures and humidity values for the RXi2-UP IPC are provided in the
following table.
Table 8-3
Temperature Specifications
Item
Level A
Temperature
Storage
-40 to 85°C (-40 to 185 °F)
Operating
-40 up to 70°C (-40 to 158 °F) *
Humidity
Operating
5 to 95% rH, non-condensing, at 40°C (104 °F)
Storage
* Upper temperature range depends on the CPU SKU, size of the enclosure, number of
plug-in PCIe cards, mounting and orientation of the unit and software load that is being
executed. Please contact technical support for further guidance.
8.2.2
Shock and Vibration without 2.5 inch Mass Storage
The RXi2-UP IPC without 2.5-inch mass storage options is designed to meet the shock and
vibration values listed in the following table.
Table 8-4
Shock and Vibration Specifications without Additional 2.5 inch Mass
Storage
Item
Vita 47 V1
Vibration
Spectrum
5 to 100 Hz
Acceleration
2 g RMS
Shock
Half sine or sawtooth
20 g
Duration
11 ms
8.2.3
Shock and Vibration with 2.5 inch Mass Storage
Due to additional interchangeable non-rugged mechanical parts, Emerson does not
recommend exposing the system to shock and vibration.
8.2.4
Altitude
Altitude air pressure and ambient temperature influence the thermal operation of the
components described in this document. They have been developed and tested at ~500 m
(1650 ft) above sea level at a typical ambient temperature of 20°C (68 °F). Because of only
marginal variations within a limited range of altitudes, this product operates as specified
within altitudes from sea level to 1,000 m (6,560 ft), depending on the level. This is
regarding the temperature ranges of air-cooled versions.