Hardware Reference Manual
Specifications
GFK-3022E
September 2021
Specifications
53
Maximum altitude for the RXi2
–
XP IPC is specified in the following table.
Table 7-5
Maximum Altitude
Item
Level A
Maximum Altitude
Operating
2 km (6,600 ft)
Storage
12 km (40,000 ft)
7.2.5
Regulations and Certification
Table 7-6
Regulations and Certification
Item
Specification
EMC
EMC Directive 2014/30/EU
EN 61000-6-4 Emission standard for industrial environments
EN 61000-6-2 Immunity standard for industrial environments
FCC Part 15 B
This device complies with part 15 of the FCC Rules. Operation is subject to the
following two conditions: (1) This device may not cause harmful interference,
and (2) this device must accept any interference received, including
interference that may cause undesired operation.
CAN ICES-3 (A)/NMB-3(A)
Product Safety
LVD Directive 2014/35/EU
IEC 62368-1 2
nd
Edition
UL 62368-1 (UL file number E214940)
UKCA
Emerson Process Management Shared Service Ltd
Meridan East, Meridan Business Park, Leicester LE19 1UX United Kingdom
Figure 7-1
RXi2-XP Data Nameplate
7.2.6
Battery
The RXi2-XP IPC contains a CR2032 lithium coin battery. The maximum current used by the
bCOM6L18 module is 6uA. Depending on the operating hours and temperature, the estimated
battery life is 2 to 10 years. Battery current is not used when the RXi2-XP IPC is supplied with 24
V.