sdU dC Ups wirinG diaGram - dC Ups with external Battery modUle sdU 24-Batem

note: 

Only one (1) SDU 24-BATEM module can be connected with the power module SDU 10-24B or SDU 20-24B.

sdU 24-Batem Battery replaCement instrUCtions

!

   

caution – 

A battery can present a risk of electrical shock and high short circuit current. The following precautions should be observed before replacing 

 

the batteries:

• 

Remove rings, watches, and other metal objects.

•  Do not lay tools or other metal objects on top of the batteries.

•  Do not dispose of batteries in a fire. The batteries may explode.

•  Dispose of old batteries according to local codes.

!

   

caution – 

ELECTRICAL SAFETY PRE-CAUTIONS MUST BE FOLLOWED WHEN INSTALLING OR SERVICING THIS EQUIPMENT. TO PREVENT 

RISK OF ELECTRICAL SHOCK, TURN OFF AND LOCK OUT ALL POWER SOURCES TO THE UNIT BEFORE MAKING ELECTRICAL CONNECTIONS 

OR SERVICING.

!

   

caution – 

WHEN REMOVING AND INSTALLING THE NEW BATTERIES, EXTREME CARE MUST BE USED NOT TO SHORT METAL CHASSIS 

PARTS ACROSS THE BATTERY TERMINALS AND NOT TO SHORT THE BATTERIES TO EACH OTHER OR PERSONAL INJURY MAY RESULT.

note:

 Caution should be exercised when replacing the batteries because the load is unprotected from disturbances and power outages during this procedure.

sdu 24-batem batteries replacement

The following battery type must be used as a replacement in this product.

manufacturer

type

rating

CsB

GP1272

12 V dc, 7.2 Ah

Summary of Contents for SDU 24-BATEM

Page 1: ... harmful to skin and eyes It may be toxic For battery recycling information contact CSB recycling network at 1 800 738 7372 what s included 1 SDU 24 BATEM External battery module 2 SDU 24 EXTBC6 Pair of 6 foot polarized cables for connecting the external battery module to the power module NOTE The circuit breaker must be in the open position O prior to installation SDU 24 BATEM Installation The SD...

Page 2: ...A 1 EBP 135 52 28 19 14 SDU 20 24B with SDU 24 BATEM Load 20 4A 40 8A 60 12A 80 16A 100 20A 1 EBP 48 17 9 6 4 SDU 24 batem specifications Parameter SDU 24 BATEM Nominal Voltage 24 VDC Protection Circuit Breaker 24V 25A Charging Current 1 2 Enclosure Dimension in mm 11 5 x 5 57 x 4 57 292 x 142 x 116 Enclosure Type NEMA 1 Terminal Connector Type Polarized Powerpole Connectors Batteries Replaceable ...

Page 3: ...e Dispose of old batteries according to local codes CAUTION ELECTRICAL SAFETY PRE CAUTIONS MUST BE FOLLOWED WHEN INSTALLING OR SERVICING THIS EQUIPMENT TO PREVENT RISK OF ELECTRICAL SHOCK TURN OFF AND LOCK OUT ALL POWER SOURCES TO THE UNIT BEFORE MAKING ELECTRICAL CONNECTIONS OR SERVICING CAUTION WHEN REMOVING AND INSTALLING THE NEW BATTERIES EXTREME CARE MUST BE USED NOT TO SHORT METAL CHASSIS PA...

Page 4: ...to Replace the Batteries Step 1 Remove four 4 screws from cover and slide cover forward off enclosure Step 2 Remove wires from battery posts Step 3 Remove four 4 screws from enclosure but secure bracket in place and then slide bracket forward from enclosure Step 4 Remove failed batteries and insert new Replaceable Batteries ...

Page 5: ...rs 2021 Emerson Electric Co All rights reserved United States Headquarters Appleton Grp LLC 9377 W Higgins Road Rosemont IL 60018 United States T 1 800 621 1506 Australia Sales Office Bayswater Victoria T 61 3 9721 0348 Europe ATX SAS Espace Industriel Nord 35 rue André Durouchez CS 98017 80084 Amiens Cedex 2 France T 33 3 2254 1390 China Sales Office Shanghai T 86 21 3338 7000 Canada EGS Electric...

Reviews: