background image

5

Reference Manual 

00809-0100-4423, Rev AB

Smart Wireless Navigator

May 2014

Smart Wireless Navigator

1.2.4

Windows user permissions

When installing the Navigator, it is necessary to consider user permissions. The default user for 
this computer is an Administrator user. An Administrator has privileges to add or delete 
programs, among other capabilities. To restrict the General Navigator user from these 
privileges, create a General User account in the Control Panel. It is recommended to run the 
Navigator on a Windows user with the least privileges possible.

1.2.5

Windows passwords 

When installing the Navigator, it is strongly recommended, for security purposes, to change the 
password for the Windows log in. Follow best practices and site/corporate IT policies to create a 
strong, non-default password. 

1.2.6

Windows updates

It is strongly recommended to keep the computer up to date with the latest Windows patches 
and security updates. Follow site or corporate IT and security policies when implementing and 
managing the Navigator system.

1.3

Launching Navigator

After logging into the Navigator workstation, the Navigator program will auto launch. Please 
allow time for Navigator to load; this may be several minutes for initial launch.

1.4

Navigator security 

A user must be logged into the Smart Wireless Navigator to access the information 
and launch the programs it contains. To log in to Navigator, simply click the “log in” 
button in the Title Bar. A prompt will ask for a username and password. Enter the 

appropriate username and password. Several design tools and applications may require a log in.

1.4.1

Navigator passwords

The Smart Wireless Navigator has two levels of user permissions, administrative and general 
user. There is one administrative account and three general accounts. The administrative 
account, “Supervisor,” has a default password of “Admin”. 

When commissioning the Navigator, it is strongly recommended, for security purposes, to 
change the password for the Navigator profile log ins. Follow best practices and site/corporate 
IT policies to create strong, non-default passwords.

The Administrator has the authority set up and change all the user accounts and 
passwords, but the usernames cannot be changed. Click on the “Settings” button in 
the Function bar. The change password capability can be found on the bottom of the 
screen.

Summary of Contents for Smart Wireless Navigator

Page 1: ...Reference Manual 00809 0100 4423 Rev AB May 2014 Emerson Smart Wireless Navigator ...

Page 2: ...5 Navigator security page 5 Adding networks to Navigator page 7 Understanding the Navigator general layout and terminology page 9 Using the Navigator for network planning and commissioning page 11 Using the Navigator for network management page 13 Using the Navigator for network maintenance page 16 Advanced Navigator functions page 18 Shutting down Navigator page 19 Service and troubleshooting pag...

Page 3: ...ttached licensing dongle Quantity 1 USB keyboard Quantity 1 USB mouse Quantity 1 6 power cord for computer tower NEMA 5 15 Type B 125 V Quantity 3 Additional power cords possible if designated when ordering 6 power cords one for computer tower two for displays Quantity 1 Setup and Features Information Booklet Quantity 1 Safety and Regulatory Information Booklet Quantity 1 Smart Wireless Navigator ...

Page 4: ...tion a Username Administrator b Password navigator 1 2 3 Assigning an IP address By default the Navigator is set up to connect to a dynamic IP architecture and be assigned an IP address by dynamic IP address allocation DHCP Consult your IT department to determine if your site runs a dynamic or static architecture All static IP information will come from IT A static IP architecture means that a spe...

Page 5: ...er logging into the Navigator workstation the Navigator program will auto launch Please allow time for Navigator to load this may be several minutes for initial launch 1 4 Navigator security A user must be logged into the Smart Wireless Navigator to access the information and launch the programs it contains To log in to Navigator simply click the log in button in the Title Bar A prompt will ask fo...

Page 6: ...erent Server Plus Station if AMS Device Manager is closed on the Client SC Station 1 In Network Configuration on the Client SC Station remove all configured system interfaces other than HART Modem 2 Select Start All Programs AMS Device Manager Server Plus Connect 3 Select the desired Server Plus Station PC from the Server Plus Station drop down list or enter the PC name in the box and click Connec...

Page 7: ...ys option When this box is checked networks can be added or removed from the Detailed Gateway Dashboard Display Field Figure 1 1 Gateway configuration adding new gateway option Click the Home button From the Home screen select the section or area to which the Gateway should be added Figure 1 2 Area selection tab To add a Gateway type the IP address in the available white space Press the Enter butt...

Page 8: ...tered limited to eighteen characters Figure 1 5 Gateway navigation tab configuration 1 5 2 Adding networks to AMS Wireless Configurator 1 Launch the Network Configuration utility a Click the Windows Start button from the main taskbar b Click All Programs c Open the AMS Wireless Configurator folder d Click Network Configuration 2 Click Add 3 Select Wireless Network from the list of networks in the ...

Page 9: ... instructions SteamLogic will need to be registered before it can be commissioned Register online as outlined in the product manual located in the Navigator or program help menu 1 Click the Set Up tab 2 Enter the network IP address HART IP Port and Descriptions in the fields and click Save 1 6 Understanding the Navigator general layout and terminology Every screen in the Smart Wireless Navigator c...

Page 10: ...buttons will return the display field to the last screen shown either back in navigation or forward in navigation Trends Opens Trending function Description on page 19 Reports Opens a sub menu that allows a user to generate a report on network health or power module status Design Opens a sub menu that contains all functions related to design The sub menu contains Gateway Interface Asset Management...

Page 11: ... drop capability to add devices The planning tool can check the design against Emerson Wireless best practices and graphically show deviations enabling pre installation optimization measures to be taken Locate the product manual in the Navigator or program Help menu for guidance on product functionality and additional features 1 7 2 Smart Wireless Gateway Capacity Estimator An accurate evaluation ...

Page 12: ...ill contain an integrated AMS Wireless Configurator or will connect to an existing AMS Device Manager A username and password is required to access these tools This will be different from the Navigator username and password Locate the product manual in the Navigator or program Help menu for guidance on product functionality and additional features 1 7 5 Gateway interface Once a Gateway has been ad...

Page 13: ...tworks with alerts check the Filter Alerts checkbox in the upper left hand corner of the display field The health status indicators represent the most severe alerts present in that network To investigate further and identify the root of the problem click on the Gateway tag for a device dashboard view Figure 1 12 Device dashboard view The different levels of dashboards are explained here Gateway or...

Page 14: ...m it has space designated for communications status tag device status and battery status The alerts shown on this dashboard will represent the most critical alerts present on the entire network Detailed device dashboard This is an example of a Detailed Device Dashboard From left to right on the top it has space designated for communications status device tag device status and battery status The De...

Page 15: ...w Battery Change Soon A Power Module exists within this category with a low battery Schedule maintenance to replace soon Critical Battery Change Now A Power Module within this category with a critical battery Schedule maintenance to replace now Good Communication Gateway ID Bar Gateway and Device Dashboards Detailed Gateway and Detailed Device Dashboards All Gateways and devices within this catego...

Page 16: ...ch contains two options for reports The reports are organized by order of severity with the most critical alerts at the top of the report The report can be printed by connecting a printer to the Navigator workstation and selecting the Print button on the function bar When accessed from the Home screen the reports will contain all alerts for all networks If maintenance is being performed on a speci...

Page 17: ... in the All Alerts report contains the same information as the Power Module Alerts report The Communication Alerts contain communication alerts such as deviations from network design best practices and communication failures Note The network design best practice alerts can be disabled by logging into an Administrator account and accessing the Settings page 1 9 3 Navigator maintenance The Smart Wir...

Page 18: ...tures The SteamLogic application can be accessed by clicking on the Applications folder in the Function bar 1 10 2 Add new applications The Smart Wireless Navigator enables the addition of secondary applications that may be useful and aid network management an example being the SteamLogic software that comes preloaded To add a new application log in as an Administrative user Click on the Settings ...

Page 19: ...10 4 Navigator user preferences Language The Smart Wireless Navigator program is available in English and German To change the language access the Settings screen and select the flag of the desired language Background color The background color of the Smart Wireless Navigator is available in gray and white To change the color access the Settings screen and select the desired color 1 11 Shutting do...

Page 20: ...enced Note Device is present after deleting it from the Gateway list It can take up to 30 days for a deletion to sync with the Navigator For guidance or assistance in other errors contact the Rosemount customer support organization or your local Emerson representative Description Navigator error Hardware licensing dongle is missing The Navigator has been loaded with the maximum number of Gateways ...

Page 21: ...21 Reference Manual 00809 0100 4423 Rev AB Smart Wireless Navigator May 2014 Smart Wireless Navigator ...

Page 22: ...9 6188 992 112 Emerson Process Management Asia Pacific Private Limited 1 Pandan Crescent Singapore 128461 T 65 6777 8211 F 65 6777 0947 Enquiries AP EmersonProcess com Emerson Process Management Rosemount Division 8200 Market Boulevard Chanhassen MN 55317 USA T U S 1 800 999 9307 T International 952 906 8888 F 952 906 8889 www rosemount com Emerson Process Managment No 6 North Street Hepingli Dong...