Table 9-13 Temperature thresholds for fan operation
This value can be used to trim out any offset from the user input signal
Drive size
Fan threshold
Lower fan threshold
Upper fan threshold
SP0xxx
TBA
N/A
N/A
SP1xxx
60
N/A
N/A
SP2xxx
60
N/A
N/A
SP3xxx
N/A
55
70
SP4xxx
N/A
55
62
SP5xxx
N/A
55
62
SP6xxx
N/A
55
65
SPMxxxx
N/A
55
65
7.07
T5/6 analogue input 1 offset trim
Drive mode
Regen
Coding
Bit
SP
FI
DE Txt VM DP ND RA NC NV
PT
US RW BU
PS
3
1
1
Range
Regen
±10.000 %
Default
Regen
0.000
Update rate
Background
7.08
T5/6 analogue input 1 scaling
Drive mode
Regen
Coding
Bit
SP
FI
DE Txt VM DP
ND
RA NC NV
PT
US RW BU
PS
3
1
1
1
Range
Regen
0.000 to 4.000
Default
Regen
1.000
Update rate
Background
7.09
T5/6 analogue input 1 invert
Drive mode
Regen
Coding
Bit
SP
FI
DE Txt VM DP
ND
RA NC NV
PT
US RW BU
PS
1
1
1
Default
Regen
0
Update rate
Background read
7.10
T5/6 analogue input 1 destination
Drive mode
Regen
Coding
Bit
SP
FI
DE Txt VM DP
ND
RA NC NV
PT
US RW BU
PS
1
2
1
1
1
1
Range
Regen
Pr
0.00
to Pr
21.51
Default
Regen
Pr
0.00
Update rate
Background