Unidrive SP Regen Installation Guide
www.controltechniques.com Issue Number: 2
Table 3-4 690V Drive ratings (690V ±10%)
The above current ratings are given for max 40
°
C (104
°
F), and 3.0 kHz switching. Derating is required for higher switching frequencies, ambient
temperature >40
°
C (104
°
F) and high altitude. For further information, refer to both the
Unidrive SP and SPM User Guides
.
Model
Normal Duty
Heavy Duty
Maximum
continuous
output current
Nominal
power
at 690V
Motor
power
at 690V
Maximum
continuous
output current
Nominal
power
at 690V
Motor
power
at 690V
A
kW
hp
A
kW
hp
4601
22
18.5
25
19
15
20
4602
27
22
30
22
18.5
25
4603
36
30
40
27
22
30
4604
43
37
50
36
30
40
4605
52
45
60
43
37
50
4606
62
55
75
52
45
60
5601
84
75
100
63
55
75
5602
99
90
125
85
75
100
6601
125
110
150
100
90
125
6602
144
132
175
125
110
150
1601
125
110
150
100
90
125
1602
144
132
175
125
110
150
1601
125
110
150
100
90
125
1602
144
132
175
125
110
150
1603
168
160
200
144
132
175
1604
192
185
250
168
160
200
4
55
56
SPMA
SPMD
NOTE
Summary of Contents for SP1201
Page 219: ......