Unidrive SP Regen Installation Guide
www.controltechniques.com Issue Number: 2
If Pr
14.18
= 0, the upper limit (Pr
14.13
) defines the maximum positive output for the PID controller and the lower limit (Pr
14.14
) defines the
minimum positive or maximum negative output. If Pr
14.18
= 1, the upper limit defines the maximum positive or negative magnitude for the PID
controller output. When any of the limits are active the integrator is held.
The value written to the destination parameter is (PID controller output x scaling) + PID main reference.
When this parameter is set to 0 the integrator operates normally. Setting this parameter to 1 will cause the integrator value to be held. Setting this
parameter does not prevent the integrator from being reset to zero if the PID controller is disabled.
See Pr
14.14
PID lower limit
Drive mode
Regen
Coding
Bit
SP
FI
DE Txt VM DP
ND
RA NC NV
PT
US RW BU PS
2
1
1
Range
Regen
±100.00 %
Default
Regen
-100.00
Update rate
Background
14.15
PID scaling
Drive mode
Regen
Coding
Bit
SP
FI
DE Txt VM DP
ND
RA NC NV
PT
US RW BU PS
3
1
1
1
Range
Regen
0.000 to 4.000
Default
Regen
1.000
Update rate
4ms
14.16
PID destination
Drive mode
Regen
Coding
Bit
SP
FI
DE Txt VM DP
ND
RA NC NV
PT
US RW BU PS
1
2
1
1
1
1
Range
Regen
Pr
0.00
to Pr
21.51
Default
Regen
Pr
0.00
Update rate
Background
14.17
PID hold integrator
Drive mode
Regen
Coding
Bit
SP
FI
DE Txt VM DP
ND
RA NC NV
PT
US RW BU PS
1
1
1
Default
Regen
0
Update rate
4ms
14.18
PID symmetrical limit enable
Drive mode
Regen
Coding
Bit
SP
FI
DE Txt VM DP
ND
RA NC NV
PT
US RW BU PS
1
1
1
Default
Regen
0
Update rate
Background