Safety
Information
Introduction
Product
information
System
design
Mechanical
installation
Electrical
installation
Getting
started
Optimisation
Parameters
Technical
data
Component
sizing
Diagnostics
148
Unidrive SP Regen Installation Guide
www.controltechniques.com Issue Number: 2
This parameter indicates that the under voltage condition is active. Normally this condition exists when the UU trip is also active. However, when the
drive first powers up it remains in the under voltage state (i.e. this parameter is active) until the DC bus voltage exceeds the under voltage restart level
(see Pr
on page 148). As the UU trip voltage level is lower than the under voltage restart level this parameter is active, but a UU trip is not active
at power up until the DC bus voltage exceeds the under voltage restart level.
This parameter is set if the drive output current is larger than 105% of rated current (Pr
5.07
) and the overload accumulator is greater than 75% to
warn that if the motor current is not reduced the drive will trip on an Ixt overload. (If the rated current (Pr
5.07
) is set to a level above the rated drive
current (Pr
11.32
) the overload alarm is given when the current is higher than 100% of rated current.)
Indicates that either the heatsink temperature is greater than or equal to 90°C, or the control board temperature is greater than or equal to 90°C, or
the IGBT junction temperature calculated from the drive thermal model is above 135°C (see Pr
Indicates that one of the drive alarms is active, i.e. Pr
10.19
= Pr
10.12
OR Pr
10.17
OR Pr
10.18
.
Contains the last 10 drive trips. Pr
10.20
is the most recent trip and Pr
10.29
the oldest. When a new trip occurs all the parameters move down one,
the current trip is put in Pr
10.20
and the oldest trip is lost off the bottom of the log.
10.16
Under voltage active
Drive mode
Regen
Coding
Bit
SP
FI
DE Txt VM DP ND RA NC NV
PT
US RW BU
PS
1
1
1
1
Update rate
Background
10.17
Overload alarm
Drive mode
Regen
Coding
Bit
SP
FI
DE Txt VM DP ND RA NC NV
PT
US RW BU
PS
1
1
1
1
Update rate
Background
10.18
Drive over temperature alarm
Drive mode
Regen
Coding
Bit
SP
FI
DE Txt VM DP ND RA NC NV
PT
US RW BU
PS
1
1
1
1
Update rate
Background
10.19
Drive warning
Drive mode
Regen
Coding
Bit
SP
FI
DE Txt VM DP ND RA NC NV
PT
US RW BU
PS
1
1
1
1
Update rate
Background
10.20
Trip 0
10.21
Trip 1
10.22
Trip 2
10.23
Trip 3
10.24
Trip 4
10.25
Trip 5
10.26
Trip 6
10.27
Trip 7
10.28
Trip 8
10.29
Trip 9
Drive mode
Regen
Coding
Bit
SP
FI
DE Txt VM DP
ND
RA NC NV PT US RW BU PS
1
1
1
1
1
1
Range
Regen
0 to 230
Update rate
Background
Summary of Contents for SP1201
Page 219: ......
Page 220: ...0471 0029 02 ...