background image

1.

Restore electrical power to the outlet box by turning
the electricity on at the main fuse box.

2.

Check the operation of the fan by gently pulling on
the pull chain switch.

3.

All fans are shipped from the factory with the
reversing switch positioned to circulate air
downward. If airflow is desired in opposite direction,
turn your fan off and wait for the blades to stop
turning, then slide the reversing switch to opposite
position, and turn fan on again. The fan blades will
turn the opposite direction and reverse the airflow.

Your fan model is equipped with a 4-position, 3-speed
pull chain switch. The operating sequence is as
follows:

Using Your Ceiling Fan

SPEED
CONTROL
SWITCH

REVERSIBLE
SWITCH

THREE-SPEED

1st Pull — High
2nd Pull — Medium
3rd Pull — Low
4th Pull — Off

To reduce the risk of fire or electrical shock, do not
use this fan with any solid-state speed control
device.

WARNING

!

8

IMPORTANT CARE INSTRUCTIONS 

for your Ceiling Fan

Periodic cleaning of your new ceiling fan is the only
maintenance that is needed.

When cleaning, use only a soft brush or lint free cloth
to avoid scratching the finish.

Abrasive cleaning agents are not required and should
be avoided to prevent damage to finish.

Maintenance

Accessories

1.

Ceiling Fan Light Kits (see store or catalog).

2.

Ceiling Fan/Light Controls (see store or catalog).

3.

Downrod Extension Kits (see store or catalog).

Do not use water when cleaning your ceiling fan. It
could damage the motor or the blades and create the
possibility of an electrical shock.

WARNING

!

This product is designed to use only those parts
supplied with this product and/or any accessories
designated specifically for use with this product by
Emerson Electric Co. Substitution of parts or
accessories not designated for use with this product
by Emerson Electric Co. could result in personal
injury or property damage.

The use of any other control not specifically
approved for this fan could result in fire, shock and
personal injury.

WARNING

!

WARNING

!

To reduce the risk of fire or electrical shock, do not
use this fan with any solid-state speed control
device.

WARNING

!

U.L. Model No.: CF742PF

Summary of Contents for SUMMER NIGHT CF742PFORB01

Page 1: ...SE INSTRUCTIONS SUMMER NIGHT 42 Damp Location Ceiling Fan Owner s Manual Model Numbers CF742PFORB01 Oil Rubbed Bronze CF742PFWW01 Appliance White Net Weight 11 7 Lbs Questions problems missing parts Before returning to the store call Emerson Electric Customer Service 8 a m 6 p m EST Monday Friday 1 800 654 3545 ...

Page 2: ...n blade clearance for an 8 foot ceiling 5 The fan must be mounted with the fan blades at least 7 feet from the floor to prevent accidental contact with the fan blades 6 Follow the recommended instructions for the proper method of wiring your ceiling fan If you do not know enough about electrical wiring have your fan installed by a licensed electrician WARNING To reduce the risk of electrical shock...

Page 3: ... the parts from the loose parts bag in a small container to keep them from being lost Unpacking Instructions For your convenience check off boxes are provided next to each assembly step As each step is completed place a check mark in the box This will insure that all steps have been completed and will be helpful in finding your place should you be interrupted Before assembly your ceiling fan refer...

Page 4: ...he setscrews Figure 1 NOTE The setscrews must be properly installed as described above or fan wobble could result 5 The fan comes with the blue black and white leads that are 80 long Before installing fan measure up approximately 6 to 9 inches above top of hanger ball downrod assembly Cut off excess leads and strip back insulation 1 2 inch from end of leads 6 Turn fan assembly upside down in prepa...

Page 5: ...oid fire or shock follow all wiring instructions carefully Any electrical work not described in these instructions should be done or approved by a licensed electrician WARNING Your new ceiling fan will require a grounded electrical supply line of 120 volts AC 60 Hz 15 amp circuit The outlet box must be securely anchored and capable of withstanding a load of at least 50 pounds If your fan is to rep...

Page 6: ...ast 50 lbs Use only a U L outlet box listed as Acceptable for Fan Support of 22 7kg 50 lbs or less WARNING To reduce the risk of fire electric shock or personal injury mount fan to outlet box marked Acceptable for Fan Support of 22 7kg 50 lbs or less and use screws supplied with outlet box Most outlet boxes commonly used for support of light fixtures are not acceptable for fan support and may need...

Page 7: ...ers over the threaded studs and installing the two knurled knobs supplied Figure 8 Tighten the knurled knobs securely until the ceiling cover fits snugly against the ceiling and the hole in the ceiling cover is clear of the downrod Your fan is now wired to be turned on and off from the fan switch CEILING COVER THREADED STUD KNURLED KNOB LOCKWASHERS 2 Figure 8 7 Check to see that all connections ar...

Page 8: ...g of your new ceiling fan is the only maintenance that is needed When cleaning use only a soft brush or lint free cloth to avoid scratching the finish Abrasive cleaning agents are not required and should be avoided to prevent damage to finish Maintenance Accessories 1 Ceiling Fan Light Kits see store or catalog 2 Ceiling Fan Light Controls see store or catalog 3 Downrod Extension Kits see store or...

Page 9: ...gainst each other or against the interior wall of the switch housing 4 Screws holding flanges to blades are loose 4 Tighten screws securely 3 Fan wobbles 1 Setscrews in motor coupling is loose 1 Tighten the setscrews securely in the motor coupling or shakes 2 Setscrew in hanger ball downrod assembly is 2 Tighten the setscrew in the hanger ball downrod excessively loose assembly 3 Screws securing f...

Page 10: ...urled Knob 2 Pull Chain Pendant Pull Chain Coupling 7 Switch Housing Cover 763112 WW 763112 OB Owner s Manual BP7313 BP7313 Repair Parts Listing 6 6 6 4 5 6 3 6 2 1 1 1 6 6 6 7 6 6 Before discarding packaging material be certain all parts have been removed HOW TO ORDER REPAIR PARTS WHEN ORDERING REPAIR PARTS ALWAYS GIVE THE FOLLOWING INFORMATION PART NUMBER PART DESCRIPTION NAME OF ITEM MODEL NUMB...

Page 11: ... to your place of purchase or you can call Emerson Customer Service at 1 800 237 6511 to obtain a return authorization and service identification tag In order for us to confirm that your Emerson Ceiling Fan is still under warranty please retain your receipt or other proof of purchase and have that information readily available when returning your Emerson Ceiling Fan to your place of purchase or up...

Page 12: ...r Service 8 a m 6 p m EST Monday Friday 1 800 654 3545 www emersonfans com Retain this manual for future use Air Comfort Products DIVISION OF EMERSON ELECTRIC CO 8100 W Florissant St Louis MO 63136 Part No F40BP73130000 Form No BP7313 Revision 130607 U L Model No CF742PF Printed in China 06 13 ...

Page 13: ...CF742PFWW01 Appliance White CF742ORB01 Oil Rubbed Bronze ...