Value Mode
Function
-6
4-20mA Stop
4-20mA with stop on current loop loss
-5
20-4mA Stop
20-4mA with stop on current loop loss
-4
4-20mA Low
4-20mA with switching to a low speed set in
Analog Input 1 Preset on Current Loss
(07.026) on current loop loss
-3
20-4mA Low
20-4mA with switching to a low speed set in
Analog Input 1 Preset on Current Loss
(07.026) on current loop loss
-2
4-20mA Hold
4-20mA with hold at level before loss on current loop loss (1)
-1
20-4mA Hold
20-4mA with hold at level before loss on current loop loss (1)
0
0-20mA
0-20mA
1
20-0mA
20-0mA
2
4-20mA Trip
4-20mA with
An Input 1 Loss
trip on current loss.
3
20-4mA Trip
20-4mA with
An Input 1 Loss
trip on current loss.
4
4-20mA
4-20mA with no action on current loop loss (input taken as 0%).
5
20-4mA
20-4mA with no action on current loop loss (input taken as 0%).
6
Voltage
Voltage input
(1) Analog input level remains at the value it had in the previous sample before the current fell below 3mA.
Parameter
07.008
Analog Input 1 Scaling
Short description
Defines the scaling factor of analog input 1
Mode
Open
‑
loop
Minimum
0.000
Maximum
10.000
Default
1.000
Units
Type
16 Bit User Save
Update Rate
Background read
Display Format
Standard
Decimal Places
3
Coding
RW
See
Analog I/O
.
Analog Input 1
(07.001) is modified by
Analog Input 1 Scaling
(07.008),
Analog Input 1 Offset
(07.030) and
Analog Input 1 Invert
(07.009) before it is routed to its destination as follows:
A
1O
=
Analog Input 1
(07.001) +
Analog Input 1 Offset
(07.030)
A
1O
is the value after the offset has been applied and is limited between -100.00% and 100.00%
A
1S
= A
1O
x
Analog Input 1 Scaling
(07.008)
A
1S
is the value after the scaling and the offset have been applied and is limited between -100.00% and 100.00%
If
Analog Input 1 Invert
(07.009) = 0 then A
1I
= A
1S
otherwise A
1I
= -A
1S
A1I is the value after the invert, scaling and offset have been applied and is the final value that is routed to the destination defined by
Analog Input 1 Destination A
(07.010) if
Analog Input 1 Control
(07.051) = 0
Analog Input 1 Destination B
(07.090) if
Analog Input 1 Control
(07.051) > 0
Parameter
07.009
Analog Input 1 Invert
Short description
Inverts the signal for analog input 1
Mode
Open
‑
loop
Minimum
0
Maximum
1
Default
0
Units
Type
1 Bit User Save
Update Rate
Background read
Display Format
Standard
Decimal Places
0
Coding
RW
See
Analog Input 1 Scaling
(07.008).
Parameter
07.010
Analog Input 1 Destination A
Short description
Defines the output parameter for analog input 1
Mode
Open
‑
loop
Minimum
0.000
Maximum
30.999
Default
1.036
Units
Type
16 Bit User Save
Update Rate
Drive reset read
Display Format
Standard
Decimal Places
3
Coding
RW, DE, PT
See
Analog Input 1 Scaling
(07.008).
Parameter
07.011
Analog Input 2 Mode
Short description
Defines the mode for analog input 2
Mode
Open
‑
loop
Minimum
6
Maximum
7
Default
6
Units
Type
8 Bit User Save
Update Rate
Background read
Display Format
Standard
Decimal Places
0
Coding
RW, TE
Value
Text
6
Volt
7
dig
See
Analog Input 2
(07.002).
The table below gives all the possible analogue input modes.
Value
Mode
Function
6
Voltage
Voltage
7
Digital
Digital
Unidrive M200 Parameter Reference Guide
Issue: 01.05.00.10
103
Summary of Contents for unidrive m200
Page 1: ...Parameter Reference Guide Unidrive M200 Open loop Mode Issue 01 05 00 10 ...
Page 30: ...30 Unidrive M200 Parameter Reference Guide Issue 01 05 00 10 ...
Page 83: ...Enable logic Unidrive M200 Parameter Reference Guide Issue 01 05 00 10 83 ...
Page 125: ...Unidrive M200 Parameter Reference Guide Issue 01 05 00 10 125 ...
Page 145: ...Unidrive M200 Parameter Reference Guide Issue 01 05 00 10 145 ...
Page 204: ...204 Unidrive M200 Parameter Reference Guide Issue 01 05 00 10 ...