See
Analog Input 1 Minimum Reference
(07.061).
Parameter
07.064
Analog Input 1 At Maximum Reference
Short description
Defines the value of analog input 1 at maximum reference
Mode
Open
‑
loop
Minimum
-100.00
Maximum
100.00
Default
100.00
Units
%
Type
16 Bit User Save
Update Rate
Background read
Display Format
Standard
Decimal Places
2
Coding
RW
See
Analog Input 1 Minimum Reference
(07.061).
Parameter
07.065
Analog Input 2 Minimum Reference
Short description
Defines the minimum reference for analog input 2
Mode
Open
‑
loop
Minimum
0.00
Maximum
100.00
Default
0.00
Units
%
Type
16 Bit User Save
Update Rate
Background read
Display Format
Standard
Decimal Places
2
Coding
RW
See graph in
Analog Input 1 Minimum Reference
(07.061).
Analog Input 2
(07.002) can be scaled and limited using the following parameters:
Analog Input 2 Minimum Reference
(07.065)
Analog Input 2 At Minimum Reference
(07.066)
Analog Input 2 Maximum Reference
(07.067)
Analog Input 2 At Maximum Reference
(07.068)
Parameters above can be selected to limit the range of
Analog Input 2
(07.002) and also scale it between the minimum and maximum reference.
If
Analog Input 2 Minimum Reference
(07.065) ≥
Analog Input 2 Maximum Reference
(07.067) then A
i2
= 0.00% whatever the input level.
Input Level is limited between
Analog Input 2 At Minimum Reference
(07.066) and
Analog Input 2 At Maximum Reference
(07.068)
Analog Input 2
(07.002) = [(
Analog Input 2 At Maximum Reference
(07.068) -
Analog Input 2 At Minimum Reference
(07.066))/(
Analog Input 2 Maximum Reference
(07.067) -
Analog Input 2 Minimum Reference
(07.065))] x (Input level -
Analog Input 2 Minimum Reference
(07.065))+
Analog Input 2 At Minimum Reference
(07.066).
Parameter
07.066
Analog Input 2 At Minimum Reference
Short description
Defines the value of analog input 2 at minimum reference
Mode
Open
‑
loop
Minimum
-100.00
Maximum
100.00
Default
0.00
Units
%
Type
16 Bit User Save
Update Rate
Background read
Display Format
Standard
Decimal Places
2
Coding
RW
See
Analog Input 2 Minimum Reference
(07.065).
Parameter
07.067
Analog Input 2 Maximum Reference
Short description
Defines the maximum reference for analog input 2
Mode
Open
‑
loop
Minimum
0.00
Maximum
100.00
Default
100.00
Units
%
Type
16 Bit User Save
Update Rate
Background read
Display Format
Standard
Decimal Places
2
Coding
RW
See
Analog Input 2 Minimum Reference
(07.065).
Parameter
07.068
Analog Input 2 At Maximum Reference
Short description
Defines the value of analog input 2 at maximum reference
Mode
Open
‑
loop
Minimum
-100.00
Maximum
100.00
Default
100.00
Units
%
Type
16 Bit User Save
Update Rate
Background read
Display Format
Standard
Decimal Places
2
Coding
RW
See
Analog Input 2 Minimum Reference
(07.065).
Parameter
07.090
Analog Input 1 Destination B
Short description
Defines the secondary destination for analog input 1
Mode
Open
‑
loop
Minimum
0.000
Maximum
30.999
Default
Units
Type
16 Bit User Save
Update Rate
Drive reset read
Display Format
Standard
Decimal Places
3
Coding
RO, DE, ND, NC, PT
See
Analog Input 1 Destination A
(07.010).
110
Unidrive M200 Parameter Reference Guide
Issue: 01.05.00.10
Summary of Contents for unidrive m200
Page 1: ...Parameter Reference Guide Unidrive M200 Open loop Mode Issue 01 05 00 10 ...
Page 30: ...30 Unidrive M200 Parameter Reference Guide Issue 01 05 00 10 ...
Page 83: ...Enable logic Unidrive M200 Parameter Reference Guide Issue 01 05 00 10 83 ...
Page 125: ...Unidrive M200 Parameter Reference Guide Issue 01 05 00 10 125 ...
Page 145: ...Unidrive M200 Parameter Reference Guide Issue 01 05 00 10 145 ...
Page 204: ...204 Unidrive M200 Parameter Reference Guide Issue 01 05 00 10 ...