Parameter
08.084
DI4 Control
Short description
Defines the behaviour of digital input 4
Mode
Open
‑
loop
Minimum
0
Maximum
26
Default
0
Units
Type
8 Bit User Save
Update Rate
Drive reset read
Display Format
Standard
Decimal Places
0
Coding
RW
See
DI1 Control
(08.081).
Parameter
08.085
DI5 Control
Short description
Defines the behaviour of digital input 5
Mode
Open
‑
loop
Minimum
0
Maximum
26
Default
0
Units
Type
8 Bit User Save
Update Rate
Drive reset read
Display Format
Standard
Decimal Places
0
Coding
RW
See
DI1 Control
(08.081).
Parameter
08.091
DO1 Control
Short description
Defines the behaviour of digital output 1
Mode
Open
‑
loop
Minimum
0
Maximum
21
Default
0
Units
Type
8 Bit User Save
Update Rate
Drive reset read
Display Format
Standard
Decimal Places
0
Coding
RW
Value Description
DI/O 01 Source/Destination B
(08.121) or
Relay 01 Source B
(08.128)
0
User defined by
Digital IO1 Source/Destination A
(08.021) or
Relay 1 Output Source A
(08.028)
00.000
1
Drive running signal (RUN)
10.002
2
Frequency arrived signal (FAR)
10.006 (at frequency)
3
Reserved
Reserved
4
Reserved
Reserved
5
Overload detection signal (OL)
10.017
6
Power off state (LU)
10.016
7
External fault stop (EXT)
10.032
8
Frequency upper limit (FHL)
10.007
9
Frequency lower limit (FLL)
10.004
10
Drive running at zero frequency
10.003
11
Reserved
Reserved
12
Reserved
Reserved
13
Reserved
Reserved
14
Drive (RDY)
10.090
15
Drive healthy
10.001
16
Reserved
Reserved
17
Reserved
Reserved
18
Brake release
12.040
19
Torque limiting
(Valid while the torque is limited by torque limiting value 1/2)
10.009
20
Forward or reverse
10.014
21
Motor 1 or 2
11.045
This offers a simple control of parameter
DI/O 01 Source/Destination B
(08.121) or
Relay 01 Source B
(08.128) to change the source.
If the control parameter (08.09x) is more than 0 then the source is defined by the relevant source parameter B (08.12x). The source parameter is written by the control selection. (e.g. If
DO1 Control
(08.091) = 10
then
DI/O 01 Source/Destination B
(08.121) = 10.003)
If the control parameter is 0 then the source is defined by the relevant source parameter A (08.02x).
Parameter
08.098
Relay 1 Control
Short description
Defines the behaviour of relay 1
Mode
Open
‑
loop
Minimum
0
Maximum
21
Default
0
Units
Type
8 Bit User Save
Update Rate
Action on exit from edit and reset
Display Format
Standard
Decimal Places
0
Coding
RW
See
DO1 Control
(08.091).
Parameter
08.121
DI/O 01 Source/Destination B
Short description
Defines the secondary source or destination parameter for digital input/output 1
Mode
Open
‑
loop
Minimum
0.000
Maximum
30.999
Default
Units
Type
16 Bit User Save
Update Rate
Drive reset read
Display Format
Standard
Decimal Places
3
Coding
RO, DE, ND, NC, PT
Refer to control parameters (
DI1 Control
(08.081) and
DO1 Control
(08.091)) for more information.
Parameter
08.122
DI/O 02 Source/Destination B
Short description
Defines the secondary source or destination parameter for digital input/output 2
Mode
Open
‑
loop
Minimum
0.000
Maximum
30.999
Default
Units
Type
16 Bit User Save
Update Rate
Drive reset read
Display Format
Standard
Decimal Places
3
Coding
RO, DE, ND, NC, PT
Refer to control parameters (
DI1 Control
(08.081) for more information.
120
Unidrive M200 Parameter Reference Guide
Issue: 01.05.00.10
Summary of Contents for unidrive m200
Page 1: ...Parameter Reference Guide Unidrive M200 Open loop Mode Issue 01 05 00 10 ...
Page 30: ...30 Unidrive M200 Parameter Reference Guide Issue 01 05 00 10 ...
Page 83: ...Enable logic Unidrive M200 Parameter Reference Guide Issue 01 05 00 10 83 ...
Page 125: ...Unidrive M200 Parameter Reference Guide Issue 01 05 00 10 125 ...
Page 145: ...Unidrive M200 Parameter Reference Guide Issue 01 05 00 10 145 ...
Page 204: ...204 Unidrive M200 Parameter Reference Guide Issue 01 05 00 10 ...