VM_SPEED_FREQ_REF_UNIPOLAR[MIN] = 0.00
Identifier
VM_SPEED_FREQ_USER_REFS
Description
Range applied to analogue reference parameters
Units
Hz
Range of [MIN]
-550.00 to 550.00
Range of [MAX]
0.00 to 550.00
This variable maximum is applied to
Analogue Reference 1
(01.036),
Analogue Reference 2
(01.037) and
Keypad Reference
(01.017).
The maximum applied to these parameters is the same as other frequency reference parameters.
VM_SPEED_FREQ_USER_REFS [MAX] = VM_SPEED_FREQ_REF[MAX]
However the minimum is dependent on
Negative Reference Clamp Enable
(01.008) and
Bipolar Reference Enable
(01.010).
Negative Reference
Clamp Enable
(01.008)
Bipolar
Reference
Enable
(01.010)
VM_SPEED_FREQ_USER_REFS[MIN]
0
0
If
Select Motor 2 Parameters
(11.045) = 0
Minimum Reference
Clamp
(01.007), otherwise
M2 Minimum Reference Clamp
(21.002)
0
1
-VM_SPEED_FREQ_REF[MAX]
1
0
0.00
1
1
-VM_SPEED_FREQ_REF[MAX]
Note - Parameter 11.045 is not available on M100/M101 and so only the Motor 1 parameters are relevant.
Identifier
VM_SUPPLY_LOSS_LEVEL
Description
Range applied to the supply loss threshold
Units
V
Range of [MIN]
0 to 1150
Range of [MAX]
0 to 1150
VM_SUPPLY_LOSS_LEVEL[MAX] = VM_DC_VOLTAGE_SET[MAX]
VM_SUPPLY_LOSS_LEVEL[MIN] is drive voltage rating dependent. See the table below.
Voltage level
200V 400V 575V (1) 690V (2)
VM_SUPPLY_LOSS_LEVEL[MIN]
205
410
540
540
(1) Unidrive M frame size 5 and above only
(2) Unidribe M frame size 7 and above only
Identifier
VM_TORQUE_CURRENT
Description
Range applied to torque and torque producing current parameters.
Units
%
Range of [MIN]
-1000.0 to 0.0
Range of [MAX]
0.0 to 1000.0
Select Motor 2 Parameters
(11.045)
VM_TORQUE_CURRENT[MAX]
0
VM_MOTOR1_CURRENT_LIMIT[MAX]
1
VM_MOTOR2_CURRENT_LIMIT[MAX]
VM_TORQUE_CURRENT[MIN] = -VM_TORQUE_CURRENT[MAX]
Identifier
VM_TORQUE_CURRENT_UNIPOLAR
Description
Unipolar version of VM_TORQUE_CURRENT
Units
%
Range of [MIN]
0.0
Range of [MAX]
0.0 to 1000.0
VM_TORQUE_CURRENT_UNIPOLAR[MAX] = VM_TORQUE_CURRENT[MAX]
VM_TORQUE_CURRENT_UNIPOLAR[MIN] =0.0
Unidrive M200 Parameter Reference Guide
Issue: 01.05.00.10
13
Summary of Contents for unidrive m200
Page 1: ...Parameter Reference Guide Unidrive M200 Open loop Mode Issue 01 05 00 10 ...
Page 30: ...30 Unidrive M200 Parameter Reference Guide Issue 01 05 00 10 ...
Page 83: ...Enable logic Unidrive M200 Parameter Reference Guide Issue 01 05 00 10 83 ...
Page 125: ...Unidrive M200 Parameter Reference Guide Issue 01 05 00 10 125 ...
Page 145: ...Unidrive M200 Parameter Reference Guide Issue 01 05 00 10 145 ...