Parameter
11.023
Serial Address
Short description
Defines the serial address of the drive
Mode
Open
‑
loop
Minimum
1
Maximum
247
Default
1
Units
Type
8 Bit User Save
Update Rate
Read on serial communications reset
Display Format
Standard
Decimal Places
0
Coding
RW, BU
Serial Address
(11.023) defines the node address for the serial comms interface in the range from 1 to 247.
Serial Address
(11.023) to
Silent Period
(11.027) can be used to change the configuration of the drive RS485 serial interface if present on the AI
adapter.
Changing the parameters does not immediately change the serial communications settings. See
Reset Serial Communications
(11.020) for more
details.
Parameter
11.024
Serial Mode
Short description
Defines the serial mode of the drive
Mode
Open
‑
loop
Minimum
0
Maximum
9
Default
0
Units
Type
8 Bit User Save
Update Rate
Read on serial communications reset
Display Format
Standard
Decimal Places
0
Coding
RW, TE
Value
Text
0
8.2NP
1
8.1NP
2
8.1EP
3
8.1OP
4
8.2NP E
5
8.1NP E
6
8.1EP E
7
8.1OP E
8
7.1EP
9
7.1OP
The core drive always uses the Modbus rtu protocol and is always a slave.
Serial Mode
(11.024) defines the data format used by the serial comms
interface. The bits in the value of
Serial Mode
(11.024) define the data format as follows. Bit 3 should always be 0 as 8 data bits are required for
Modbus rtu.
Bits
3
2
Format
Number of data bits
0 = 8 bits
1 = 7 bits
Register mode
0 = Standard
1 = Modified
Bit 2 selects either standard or modified register mode. The menu and parameter numbers are derived for each mode as given in the table below.
Standard mode is compatible with Commander SK. Modified mode is provided to allow parameter numbers up to 255 to be addressed. If any menus
contain more than 99 parameters, then these parameters cannot be accessed via Standard Modbus rtu.
Register mode Register address
Standard
(mm x 100) + ppp - 1 where mm ≤ 162 and ppp ≤ 99
Modified
(mm x 256) + ppp - 1 where mm ≤ 63 and ppp ≤ 255
Changing the parameters does not immediately change the serial communications settings. See
Reset Serial Communications
(11.020) for more
details.
Parameter
11.025
Serial Baud Rate
Short description
Defines the serial baud rate of the drive
Mode
Open
‑
loop
Minimum
1
Maximum
10
Default
6
Units
Baud
Type
8 Bit User Save
Update Rate
Read on serial communications reset
Display Format
Standard
Decimal Places
0
Coding
RW, TE
174
Unidrive M200 Parameter Reference Guide
Issue: 01.05.00.10
Summary of Contents for unidrive m200
Page 1: ...Parameter Reference Guide Unidrive M200 Open loop Mode Issue 01 05 00 10 ...
Page 30: ...30 Unidrive M200 Parameter Reference Guide Issue 01 05 00 10 ...
Page 83: ...Enable logic Unidrive M200 Parameter Reference Guide Issue 01 05 00 10 83 ...
Page 125: ...Unidrive M200 Parameter Reference Guide Issue 01 05 00 10 125 ...
Page 145: ...Unidrive M200 Parameter Reference Guide Issue 01 05 00 10 145 ...
Page 204: ...204 Unidrive M200 Parameter Reference Guide Issue 01 05 00 10 ...