Value
Text
0
110V
1
200V
2
400V
3
575V
4
690V
Drive Rated Voltage
(11.033) shows the input voltage rating of the drive.
Parameter
11.034
Drive Configuration
Short description
Defines the configuration of the drive
Mode
Open
‑
loop
Minimum
0
Maximum
9
Default
0
Units
Type
8 Bit User Save
Update Rate
Actioned on exit of edit mode and on
drive reset
Display Format
Standard
Decimal Places
0
Coding
RW, TE, PT, BU
Value
Text
Description
0
AV
Analog input 1 (voltage) Analog input 2 (voltage) selected by
terminal (Local/Remote)
1
AI
Analog input 1 (current) or Analog input 2 (voltage) selected by
terminal (Local/Remote)
2
AV.Pr
Analog input 1 (voltage) or 3 presets selected by terminal
3
AI.Pr
Analog input 1 (current) or 3 presets selected by terminal
4
Preset
Four presets selected by terminal
5
Pad
Keypad reference
6
Pad.Ref
Keypad reference with terminal control
7
E.Pot
Electronic Potentiometer
8
Torque
Torque mode, Analog input 1 (current frequency reference) or
Analog input 2 (voltage torque reference) selected by terminal
9
Pid
PID mode, Analog input 1 (current feedback source) and Analog
input 2 (voltage reference source)
This parameter is used to automatically setup the user programmable area in the level 3 parameter set according to drive configurations. Other default
values may also be changed by drive configuration. Parameters are stored in EEPROM automatically following a configuration change if the change is
made by a keypad.
Action will only occur if the drive is inactive, not in UU state and no User Actions are running. Otherwise, the parameter will return to its pre altered value
on exit from edit mode.
Parameter number
AV
AI
AV.Pr AI.Pr Preset Pad
Pad.ref E.Pot Tor
PID
Reference Selector
(01.014)
0
0
1
1
3
4
6
3
0
1
Analog Input 1 Mode
(07.007)
6
4
6
4
6
6
6
6
4
4
Analog Input 2 Mode
(07.011)
6
6
7
7
7
6
6
7
6
6
Analog Input 1 Control
(07.051)
0
0
0
0
0
0
0
0
0
0
Analog Input 1 Destination A
(07.010)
1.036 1.036 1.036 1.036 1.036 1.036 1.036
1.036 1.036 0.000
Analog Input 2 Destination A
(07.014)
1.037 1.037 1.046 1.046 1.046 1.037 1.037
9.027 4.008 0.000
Digital Input 05 Destination A
(08.025) 1.041 1.041 1.045 1.045 1.045 1.041 1.041
9.026 4.011 14.008
DI5 Control
(08.085)
0
0
0
0
0
0
0
0
0
0
Motorised Pot Destination
(09.025)
0
0
0
0
0
0
0
1.021 0
0
PID1 Reference Source
(14.003)
0
0
0
0
0
0
0
0
0
7.0021
PID1 Feedback Source
(14.004)
0
0
0
0
0
0
0
0
0
7.001
PID1 Destination
(14.016)
0
0
0
0
0
0
0
0
0
1.036
Parameter
11.035
Power Software Version
Short description
Displays the power processor firmware
Mode
Open
‑
loop
Minimum
0
Maximum
99999999
Default
Units
Type
32 Bit Volatile
Update Rate
Power-up write
Display Format
Version
Decimal Places
0
Coding
RO, ND, NC, PT
Power Software Version
(11.035) displays the drive power stage software version number in the form ww.xx.yy.
Unidrive M200 Parameter Reference Guide
Issue: 01.05.00.10
177
Summary of Contents for unidrive m200
Page 1: ...Parameter Reference Guide Unidrive M200 Open loop Mode Issue 01 05 00 10 ...
Page 30: ...30 Unidrive M200 Parameter Reference Guide Issue 01 05 00 10 ...
Page 83: ...Enable logic Unidrive M200 Parameter Reference Guide Issue 01 05 00 10 83 ...
Page 125: ...Unidrive M200 Parameter Reference Guide Issue 01 05 00 10 125 ...
Page 145: ...Unidrive M200 Parameter Reference Guide Issue 01 05 00 10 145 ...
Page 204: ...204 Unidrive M200 Parameter Reference Guide Issue 01 05 00 10 ...