Parameter
12.028
Variable Selector 2 Source 1
Short description
Defines the 1st source parameter for variable selector 2
Mode
Open
‑
loop
Minimum
0.000
Maximum
30.999
Default
0.000
Units
Type
16 Bit User Save
Update Rate
Drive reset read
Display Format
Standard
Decimal Places
3
Coding
RW, PT, BU
See
Variable Selector 1 Source 1
(12.008).
Parameter
12.029
Variable Selector 2 Source 2
Short description
Defines the 2nd source parameter for variable selector 2
Mode
Open
‑
loop
Minimum
0.000
Maximum
30.999
Default
0.000
Units
Type
16 Bit User Save
Update Rate
Drive reset read
Display Format
Standard
Decimal Places
3
Coding
RW, PT, BU
See
Variable Selector 1 Source 1
(12.008).
Parameter
12.030
Variable Selector 2 Mode
Short description
Defines the mode for variable selector 2
Mode
Open
‑
loop
Minimum
0
Maximum
9
Default
0
Units
Type
8 Bit User Save
Update Rate
Background read
Display Format
Standard
Decimal Places
0
Coding
RW, TE
Value
Text
0
0
1
1
2
2
3
3
4
4
5
5
6
6
7
7
8
8
9
9
See
Variable Selector 1 Source 1
(12.008).
Parameter
12.031
Variable Selector 2 Destination
Short description
Defines the destination parameter for variable selector 2
Mode
Open
‑
loop
Minimum
0.000
Maximum
30.999
Default
0.000
Units
Type
16 Bit User Save
Update Rate
Drive reset read
Display Format
Standard
Decimal Places
3
Coding
RW, DE, PT, BU
See
Variable Selector 1 Source 1
(12.008).
Parameter
12.032
Variable Selector 2 Output
Short description
Displays the output of variable selector 2
Mode
Open
‑
loop
Minimum
-100.00
Maximum
100.00
Default
Units
%
Type
16 Bit Volatile
Update Rate
4ms write
Display Format
Standard
Decimal Places
2
Coding
RO, ND, NC, PT
See
Variable Selector 1 Source 1
(12.008).
Parameter
12.033
Variable Selector 2 Source 1 Scaling
Short description
Defines the scaling for the 1st input for variable selector 2
Mode
Open
‑
loop
Minimum
-4.000
Maximum
4.000
Default
1.000
Units
Type
16 Bit User Save
Update Rate
4ms read
Display Format
Standard
Decimal Places
3
Coding
RW
See
Variable Selector 1 Source 1
(12.008).
Parameter
12.034
Variable Selector 2 Source 2 Scaling
Short description
Defines the scaling for the 2nd input for variable selector 2
Mode
Open
‑
loop
Minimum
-4.000
Maximum
4.000
Default
1.000
Units
Type
16 Bit User Save
Update Rate
4ms read
Display Format
Standard
Decimal Places
3
Coding
RW
See
Variable Selector 1 Source 1
(12.008).
196
Unidrive M200 Parameter Reference Guide
Issue: 01.05.00.10
Summary of Contents for unidrive m200
Page 1: ...Parameter Reference Guide Unidrive M200 Open loop Mode Issue 01 05 00 10 ...
Page 30: ...30 Unidrive M200 Parameter Reference Guide Issue 01 05 00 10 ...
Page 83: ...Enable logic Unidrive M200 Parameter Reference Guide Issue 01 05 00 10 83 ...
Page 125: ...Unidrive M200 Parameter Reference Guide Issue 01 05 00 10 125 ...
Page 145: ...Unidrive M200 Parameter Reference Guide Issue 01 05 00 10 145 ...
Page 204: ...204 Unidrive M200 Parameter Reference Guide Issue 01 05 00 10 ...