Menu 14 Single Line Descriptions −
User PID Controller
Mode: Open
‑
loop
Parameter
Range
Default
Type
14.001 PID1 Output
±100.00 %
RO
Num
ND
NC
PT
14.002 PID1 Feed
‑
forward Reference Source
0.000 to 30.999
0.000
RW
Num
PT
US
14.003 PID1 Reference Source
0.000 to 30.999
0.000
RW
Num
PT
US
14.004 PID1 Feedback Source
0.000 to 30.999
0.000
RW
Num
PT
US
14.005 PID1 Reference Invert
Off (0) or On (1)
Off (0)
RW
Bit
US
14.006 PID1 Feedback Invert
Off (0) or On (1)
Off (0)
RW
Bit
US
14.007 PID1 Reference Slew Rate
0.0 to 3200.0 s
0.0 s
RW
Num
US
14.008 PID1 Enable
Off (0) or On (1)
Off (0)
RW
Bit
US
14.009 PID1 Enable Source 1
0.000 to 30.999
0.000
RW
Num
PT
US
14.010 PID1 Proportional Gain
0.000 to 4.000
1.000
RW
Num
US
14.011 PID1 Integral Gain
0.000 to 4.000
0.500
RW
Num
US
14.012 PID1 Differential Gain
0.000 to 4.000
0.000
RW
Num
US
14.013 PID1 Output Upper Limit
0.00 to 100.00 %
100.00 %
RW
Num
US
14.014 PID1 Output Lower Limit
±100.00 %
-100.00 %
RW
Num
US
14.015 PID1 Output Scaling
0.000 to 4.000
1.000
RW
Num
US
14.016 PID1 Destination
0.000 to 30.999
0.000
RW
Num
DE
PT
US
14.017 PID1 Integral Hold
Off (0) or On (1)
Off (0)
RW
Bit
14.018 PID1 Symmetrical Limit Enable
Off (0) or On (1)
Off (0)
RW
Bit
US
14.019 PID1 Feed
‑
forward Reference
±100.00 %
RO
Num
ND
NC
PT
14.020 PID1 Reference
±100.00 %
RO
Num
ND
NC
PT
14.021 PID1 Feedback
±100.00 %
RO
Num
ND
NC
PT
14.022 PID1 Error
±100.00 %
RO
Num
ND
NC
PT
14.023 PID1 Reference Scaling
0.000 to 4.000
1.000
RW
Num
US
14.024 PID1 Feedback Scaling
0.000 to 4.000
1.000
RW
Num
US
14.025 PID1 Digital Reference
±100.00 %
0.00 %
RW
Num
US
14.026 PID1 Digital Feedback
±100.00 %
0.00 %
RW
Num
US
14.027 PID1 Enable Source 2
0.000 to 30.999
0.000
RW
Num
PT
US
RW Read / Write
RO Read-only
Bit Bit parameter
Txt Text string
Date Date parameter
Time Time parameter
Chr Character parameter Bin Binary parameter
IP IP address
Mac MAC address
Ver Version number SMP Slot, menu, parameter
Num Number parameter
DE Destination
ND No
default value
RA Rating dependent
NC Non-copyable
PT Protected
FI Filtered
US User save
PS Power-
down save
202
Unidrive M200 Parameter Reference Guide
Issue: 01.05.00.10
Summary of Contents for unidrive m200
Page 1: ...Parameter Reference Guide Unidrive M200 Open loop Mode Issue 01 05 00 10 ...
Page 30: ...30 Unidrive M200 Parameter Reference Guide Issue 01 05 00 10 ...
Page 83: ...Enable logic Unidrive M200 Parameter Reference Guide Issue 01 05 00 10 83 ...
Page 125: ...Unidrive M200 Parameter Reference Guide Issue 01 05 00 10 125 ...
Page 145: ...Unidrive M200 Parameter Reference Guide Issue 01 05 00 10 145 ...
Page 204: ...204 Unidrive M200 Parameter Reference Guide Issue 01 05 00 10 ...