Reference Selected Indicator
(01.049)
Preset Selected Indicator
(01.050)
Reference
1
1
Analog Reference 1
(01.036)
1
>1
Preset reference defined by the value of
Preset Selected Indicator
(01.050)
2
1
Analog Reference 2
(01.037)
2
>1
Preset reference defined by the value of
Preset Selected Indicator
(01.050)
3
x
Preset reference defined by the value of
Preset Selected Indicator
(01.050)
4
x
Keypad Control Mode Reference
(01.017)
5
x
Not used
6
x
Keypad Control Mode Reference
(01.017)
If
Reference Selected Indicator
(01.049) = 4 the
Keypad Control Mode Reference
(01.017) is used and the sequencer operates in keypad mode where the start
and stop functions are provided from the drive keypad.
Jog Select
(01.013) is always 0 when keypad mode is active.
If
Reference Selected Indicator
(01.049) = 6 the
Keypad Control Mode Reference
(01.017) is used, but keypad start and stop switches are not active.
Parameter
01.015
Preset Selector
Short description
Defines which preset is used for the reference
Mode
Open
‑
loop
Minimum
0
Maximum
9
Default
0
Units
Type
8 Bit User Save
Update Rate
4ms read
Display Format
Standard
Decimal Places
0
Coding
RW
See
Reference Selector
(01.014).
Parameter
01.016
Preset Selector Timer
Short description
Defines the time between changes of preset selector
Mode
Open
‑
loop
Minimum
0.0
Maximum
400.0
Default
10.0
Units
s
Type
16 Bit User Save
Update Rate
Background read
Display Format
Standard
Decimal Places
1
Coding
RW
If
Preset Selector
(01.015) = 9 then
Preset Selected Indicator
(01.050) is incremented by one at intervals defined by
Preset Selector Timer
(01.016). When
Preset Selected Indicator
(01.050) has a value of 8 and is incremented it rolls over to 1. If
Preset Selector Timer Reset
(01.048) = 1 and
Preset Selector
(01.015) = 9, then
Preset Selected Indicator
(01.050) is held at 1 and the internal timer is reset.
Parameter
01.017
Keypad Control Mode Reference
Short description
Displays the value of the keypad reference
Mode
Open
‑
loop
Minimum
−VM_SPEED_FREQ_USER_REFS
Maximum
VM_SPEED_FREQ_USER_REFS
Default
0.00
Units
Hz
Type
32 Bit Power Down Save
Update Rate
4ms read
Display Format
Standard
Decimal Places
2
Coding
RO, VM, NC, PT
See
Reference Selector
(01.014) for selection of the
Keypad Control Mode Reference
(01.017).
Parameter
01.021
Preset Reference 1
Short description
Defines the value for preset reference 1
Mode
Open
‑
loop
Minimum
−VM_SPEED_FREQ_REF
Maximum
VM_SPEED_FREQ_REF
Default
0.00
Units
Hz
Type
32 Bit User Save
Update Rate
4ms read
Display Format
Standard
Decimal Places
2
Coding
RW, VM
See
Reference Selector
(01.014).
Parameter
01.022
Preset Reference 2
Short description
Defines the value for preset reference 2
Mode
Open
‑
loop
Minimum
−VM_SPEED_FREQ_REF
Maximum
VM_SPEED_FREQ_REF
Default
0.00
Units
Hz
Type
32 Bit User Save
Update Rate
4ms read
Display Format
Standard
Decimal Places
2
Coding
RW, VM
See
Reference Selector
(01.014).
Unidrive M200 Parameter Reference Guide
Issue: 01.05.00.10
21
Summary of Contents for unidrive m200
Page 1: ...Parameter Reference Guide Unidrive M200 Open loop Mode Issue 01 05 00 10 ...
Page 30: ...30 Unidrive M200 Parameter Reference Guide Issue 01 05 00 10 ...
Page 83: ...Enable logic Unidrive M200 Parameter Reference Guide Issue 01 05 00 10 83 ...
Page 125: ...Unidrive M200 Parameter Reference Guide Issue 01 05 00 10 125 ...
Page 145: ...Unidrive M200 Parameter Reference Guide Issue 01 05 00 10 145 ...
Page 204: ...204 Unidrive M200 Parameter Reference Guide Issue 01 05 00 10 ...