Trip
dcct
Value
110
Short description
DC Current transformer failure (size 5 and above)
DCCT reference out of range (size 5 and above only).
Recommended actions:
Hardware fault - contact the supplier of the drive.
Trip
Der.E
Value
246
Short description
Derivative Image error
An error has been detected in the derivative product image. The sub-trip indicated the reason for the trip.
Sub-trip
Reason
Comments
1
The derivative image is missing or is invalid
Occurs when the drive powers-up. Load valid derivative image
matching the control board hardware.
2
The derivative image does not match the control board
hardware
Occurs when the drive powers-up. Load valid derivative image
matching the control board hardware.
3
The derivative image has been changed for an image
with a different derivative number.
Occurs when the drive powers-up or the image is programmed.
The image tasks will not run.
Trip
Der.I
Value
248
Short description
Derivative program error
An error has been detected in the derivative product image. The sub-trip indicates the reason for the trip.
Unidrive M200 Parameter Reference Guide
Issue: 01.05.00.10
251
Summary of Contents for unidrive m200
Page 1: ...Parameter Reference Guide Unidrive M200 Open loop Mode Issue 01 05 00 10 ...
Page 30: ...30 Unidrive M200 Parameter Reference Guide Issue 01 05 00 10 ...
Page 83: ...Enable logic Unidrive M200 Parameter Reference Guide Issue 01 05 00 10 83 ...
Page 125: ...Unidrive M200 Parameter Reference Guide Issue 01 05 00 10 125 ...
Page 145: ...Unidrive M200 Parameter Reference Guide Issue 01 05 00 10 145 ...
Page 204: ...204 Unidrive M200 Parameter Reference Guide Issue 01 05 00 10 ...