The required change of frequency Δw = 50Hz. The acceleration and jerk are converted from the parameter values as follows:
a
Max
= 100 / ramp rate = 20.0Hz/s
J
Max
= 100 /
Max Rate Of Change Of Acceleration
(02.007) = 32.3Hz/s
2
The linear ramp time T
Linear
= Δw x a
Max
= 50.0 / 20.0 = 2.5s
The frequency change for the acceleration to reach its limit w
B
= a
Max
2
/ 2J
Max
= 20.0
2
/ (2 x 32.3) = 6.19Hz
The required frequency change for Δw = 50Hz and this is greater than 2w
B
, i.e. Δw > 2 x 6.19Hz. Therefore the time for the ramp
T
SRamp2
= (Δw / a
Max
) + (a
Max
/ J
Max
) = (50.0 / 20.0) + (20.0 / 32.3) = 2.5 + 0.62 = 3.12s
Note that the default value of
Max Rate Of Change Of Acceleration
(02.007) has been chosen so that when it is combined with the default acceleration
rate, each of the S sections of the ramp is 20% of the overall time for the frequency change, i.e. 0.62/3.12 x 100% = 20%. This is the same as if
S Ramp Set-up Mode
(02.041) = 2 and
S Ramp Percentage
(02.040) = 20% (see parameter
S Ramp Set-up Mode
(02.041) for alternative methods of
setting up the S ramp function).
If the required change of frequency had been 5.0Hz, i.e. less than 2 x wB, then the alternative equation should be used:
34
Unidrive M200 Parameter Reference Guide
Issue: 01.05.00.10
Summary of Contents for unidrive m200
Page 1: ...Parameter Reference Guide Unidrive M200 Open loop Mode Issue 01 05 00 10 ...
Page 30: ...30 Unidrive M200 Parameter Reference Guide Issue 01 05 00 10 ...
Page 83: ...Enable logic Unidrive M200 Parameter Reference Guide Issue 01 05 00 10 83 ...
Page 125: ...Unidrive M200 Parameter Reference Guide Issue 01 05 00 10 125 ...
Page 145: ...Unidrive M200 Parameter Reference Guide Issue 01 05 00 10 145 ...
Page 204: ...204 Unidrive M200 Parameter Reference Guide Issue 01 05 00 10 ...